05TA Service Manual
OPTIONS AND ACCESSORIES
8/13/01
10-18
Troubleshooting
SYMPTOM
DISPLAY
LED’s
SOLUTION
Load will not energize.
System on line.
LOAD LED not
lit.
Check control input.
Parameters will not change when
arrows pressed.
Indicates
parameters when
SETUP is pressed.
Normal.
Parameters are locked out. See “Locking
Out Setup Menu”.
LEDS blink periodically but unit
never comes up.
Occasional Flash.
Blinking.
Line voltage too low and/or phase
missing.
Control LED does not go out when
control is off.
CONTROL
LED always on.
Control input is very sensitive. Insure
control voltage < 2 volts for off condition.
System trips out on low or high line
voltage.
FAULT LED
flashes (due to
fault).
Check normal line voltage using READ
feature. Re-adjust voltage range as
required.
Output relay never turns on.
Control Mode setting is “OFF”. Press
setup to get to Control Mode then use
arrow keys to set mode to EXTERNAL.
Unit makes whistling or sizzling
sound.
Normal.
Normal.
Some sound coming from the unit is
normal and may vary with input voltage.
Summary of Contents for TUBE-ICE 05TA
Page 4: ...Vogt Tube Ice Machines Installation Service Manual and Parts Catalog 12A4171M06 05TA Model ...
Page 82: ...05TA Service Manual SERVICE OPERATIONS 8 13 01 9 18 FIGURE 9 10 Cutter Drive Parts ...
Page 95: ...05TA Service Manual OPTIONS AND ACCESSORIES 8 13 01 10 11 FIGURE 10 3 Control Panel Parts ...
Page 97: ...05TA Service Manual OPTIONS AND ACCESSORIES 8 13 01 10 13 FIGURE 10 4 Wiring Schematic ...
Page 103: ...05TA Service Manual TABLES CHARTS 8 14 01 11 1 11 Tables Charts ...