05TA Service Manual
INSTALLING YOUR TUBE-ICE
®
MACHINE
8/13/01
3-8
Ice Machine Model
05TA
05TA
Electrical Frequency, Hz.
60
50
Recommended Condenser
DD-311
DD-361
Total Heat Rejection (BTU/hr)
181,200
193,250
Fans:
Number
HP, Each
Total CFM
5
1/2
22,000
5
1/2
22,500
Full Load Amps (FLA):
3 ph., 208/230V., 60 hz.
3 ph., 460V., 60 hz.
3 ph., 190V., 50 hz.
3 ph., 380V., 50 hz.
9.0
4.5
--
--
9.0
4.5
9.0
4.5
Locked Rotor Amps (LRA):
3 ph., 208/230V., 60 hz.
3 ph., 460V., 60 hz.
3 ph., 190V., 50 hz.
3 ph., 380V., 50 hz.
33.0
16.5
--
--
--
--
33.0
16.5
Weight, lbs.:
Net
Shipping
Operating (Maximum flooded)R-404a
610
760
648
660
810
705
Condenser Dimensions, inches
A (Width)
B (Length)
C (Height)
D (Leg centerline)
E (Leg centerline)
F (Clearance below)
28 3/4”
180 1/8”
41 5/8”
27”
147 5/8”
14 5/8”
28 3/4”
180 1/8”
41 5/8”
27”
147 5/8”
14 5/8”
Recommended Line Sizes, OD
Liquid
All lengths and orientations
Discharge Gas
Vertical Up, all lengths
Horiz. or Down, < 75 ft.
Horiz. or Down > 75 ft.
1 1/8”
1 1/8”
1 1/8”
1 1/8”
1 1/8”
1 1/8”
1 1/8”
1 1/8”
Connections (Cond. & Ice Mach.):
Liquid (ODF)
Discharge Gas (ODF)
1 1/8”
1 3/8”
1 1/8”
1 3/8”
Ice Machine Model
05TA
05TA
TABLE 3-4
Air-Cooled Condenser Data
Summary of Contents for TUBE-ICE 05TA
Page 4: ...Vogt Tube Ice Machines Installation Service Manual and Parts Catalog 12A4171M06 05TA Model ...
Page 82: ...05TA Service Manual SERVICE OPERATIONS 8 13 01 9 18 FIGURE 9 10 Cutter Drive Parts ...
Page 95: ...05TA Service Manual OPTIONS AND ACCESSORIES 8 13 01 10 11 FIGURE 10 3 Control Panel Parts ...
Page 97: ...05TA Service Manual OPTIONS AND ACCESSORIES 8 13 01 10 13 FIGURE 10 4 Wiring Schematic ...
Page 103: ...05TA Service Manual TABLES CHARTS 8 14 01 11 1 11 Tables Charts ...