Operation Manual
VKI Publication #100308-003
100
System Status Screen
Code Message Displayed
Condition
Action(s) Required
--
Electronic Board Communication Lost
Please Call for Service or Press
Acknowledge to Retry
Communication between the
control board and HMI is lost.
1 - Press "Acknowledge" to reset
2 - Reboot the machine.
3 - If message persists, check the
HMI, Control Board and wiring.
B1
Blower & Fan current is over safety
level
Blower & Fan current is above the
recommended safety level. Fan may
be drawing too much power.
1 - Check the wiring and
connections for the powder system
blower.
2 - Clean any accumulation from the
blower.
3 - If message persists, replace the
powder system blower.
Blower & Fan current is under
minimum operation level
Blower & Fan current is below the
minimum operating level. Fan may
not be drawing enough power.
1 - Check wiring and connections for
the powder system blower.
2 - If message persists, replace the
powder system blower.
D2 LED in Waste Bin detector has a fault
The IR LED of the waste bin sensor
voltage is over the configured
maximum operation level.
1 - Clear the message.
2 - Reboot the machine.
3 - If message persists, replace the
waste bin presence sensor.
G1
Coffee Grinder Over Current Standby The grinder current was over the
stand by operation level.
1 - Clear the message.
2 - Reboot the machine.
Grinder Fuse Fault
Grinder fuse is in fault.
1 - Check the fuse on the control
board.
Grinder Sensor Error
Grinder Current Sensor is out of range. 1 - Clear the message.
2 - Reboot the machine.
Grinder's current is close to critical
level
Grinder current is close to maximum
operating level. Grinder may be
drawing too much power.
1 - Check to see if the grinder is
jammed (possibly a foreign object in
the grinder heads).
2 - Check the condition of the
grinder belt.
3 - Reboot the machine.
4 - If message persists, replace the
grinder.
Grinder's current is close to minimum
operation level
Grinder current is close to minimum
operating level. Grinder may not be
drawing enough power.
1 - Reboot the machine.
2 - If message persists, replace the
grinder.
Grinder's current is over safety level Grinder current has exceeded the
maximum operating level.
1 - Check to see if the grinder is
jammed (possibly a foreign object in
the grinder heads).
2 - Check the condition of the
grinder belt.
3 - Reboot the machine.
4 - If message persists, replace the
grinder.
Grinder's current is under minimum
operation level
Grinder current is below the
minimum operating level.
1 - Check the condition of the
grinder belt.
2 - Check the wiring and
connections to the grinder.
3 - The grinder may need to be
replaced.