NOTE: For multi-unit locations whereby the main water conduit is supplying
water to more than one unit (including water coolers), a separate in-line
shut off valve must be installed onto each individual equipment unit.
4.
Water Fittings & Valves - Material Requirements (Conforms to NSF-51 & NSF-61):
Fittings & valves (water supply connection - water filter head - brewing equipment):
►
NSF CONFORMING: BARB type fittings with OERTIKER clamps
►
PREFERENCE: Custom nickel plated brass
►
ALTERNATE: Stainless Steel (much more costly)
NOTE:
The shut-off valve must be easily
accessible by the customer, who
must be informed
of its location
during the installation.
MATERIAL REQUIREMENTS:
E
QUIPMENT
F
ITTING
:
Male 3/8 inch NPTF
T
UBING
(W
ATER SUPPLY TO FILTER
):
Reinforced PVC Beverage grade
T
UBING
(W
ATER FILTER TO EQUIPMENT
):
Stainless steel braided hose
Quick-connect type fittings are not approved for use with any
equipment manufactured by VKI Technologies.