132
10-4 RADIUS
10-4.1 Configuration
Web Interface
To configure a RADIUS in the web interface:
1.
Click Security, RADIUS and Configuration.
2.
Set Timeout, Retransmit, Deadtime, Key, NAS-IP-Address, NAS
IPv6-Address,NAS-Identifier.
3.
Click “Add New Entry”.
4.
Set Hostname, Auth Port, Acct Port, Timeout, Retransmit, Key.
5.
Click the Apply to save the setting.
6.
If you want to cancel the setting then you need to click the Reset button. It will revert to
previously saved values.
Figure 10-4.1: The RADIUS Configuration
Parameter description:
Global Configuration
These setting are common for all of the RADIUS servers.
Timeout :
Timeout is the number of seconds, in the range 1 to 1000, to wait for a reply from a RADIUS
server before retransmitting the request.
Retransmit :
Retransmit is the number of times, in the range 1 to 1000, a RADIUS request is retransmitted
to a server that is not responding. If the server has not responded after the last retransmit it
is considered to be dead.
Deadtime :