19.5 UDP/TCP Alert Messages
Sending Out UDP/TCP Alert Messages:
This function can be used to integrate alert messages generated by the
Switch to various “Health Monitoring” software packages. For a complete
list of messages that can be sent out by the Switch see the “SNMP Trap
States” section of this manual.
Switch Name:
The Switch can be named by entering the text into this box. This name
will be sent out in the alert messages and can be used to identify the
specific unit where the alert originated. If the box is blank, the IP address
of the Switch will be sent for identification.
UDP Alerts:
To enable or disable this function, click the down arrow located under
“UDP Alerts” and select the appropriate option.
To broadcast the alert messages, check the box next to “Broadcast”.
To send alerts to a specific IP address, type the address into the “UDP
Client IP Address” text boxes. The same Subnet mask that is used when
setting up the IP address of the Switch will also be used in the UDP
messaging. Be sure to un-check the “Broadcast” check box prior to
inputting the IP Address.
Finally input the port to be used and click the “Update” button.