Page | 28
•
Check the Port Configuration.
A port on your switch may not be
operating as you expect because it has been put into a “blocking”
state by Spanning Tree, GVRP (automatic VLANs), or LACP
(automatic trunking). (Note that the normal operation of the
Spanning Tree, GVRP, and LACP features may put the port in a
blocking state.) Or, the port just may have been configured as
disabled through software.
7.1 Table 10:
Troubleshooting
Chart
Symptom
Action
POWER LED is Off
•
Check connections between the switch, the
power cord and the wall outlet.
•
Contact your dealer for assistance.
Link LED is Off
•
Verify that the switch and attached device are
powered on.
•
Be sure the cable is plugged into the switch and
corresponding device.
•
If the switch is installed in a rack, check the
connections to the punch-down block and patch
panel.
•
Verify that the proper cable type is used and its
length does not exceed specified limits.
•
Check the adapter on the attached device and
cable connections for possible defects. Replace
the defective adapter or cable if necessary.