99
Dis-
played
fault
code
Const.
Weath.-
comp.
System char-
acteristics
Cause
Measures
98
X
X
Control mode
Lead broken,
temperature
sensor
/
Check sensor
/
on the solar control
module
99
X
X
Control mode
Lead broken,
temperature
sensor
aÖ
Check sensor
aÖ
on the solar control
module
9A
X
X
No DHW heat-
ing
Lead break,
collector tem-
perature sen-
sor
Check temperature
sensor
&
on the
solar control mod-
ule or the Vitosolic
sensor
9b
X
X
Control mode
Lead break,
cylinder tem-
perature sen-
sor
Check temperature
sensor at connec-
tion S3 to the
Vitosolic 100
9C
X
X
No DHW heat-
ing
Lead break,
cylinder tem-
perature sen-
sor
Check temperature
sensor
%
on the
solar control mod-
ule or the Vitosolic
sensor
9E
X
X
Control mode
No flow rate
in the collec-
tor circuit or
flow rate too
low, or tem-
perature lim-
iter has
responded
Check solar circuit
pump and solar cir-
cuit. Acknowledge
fault message
9F
X
X
Control mode
Solar control
module or
Vitosolic
faulty
Replace solar con-
trol module or
Vitosolic
A6
X
X
Control mode
Impressed
current anode
faulty
Replace
impressed current
anode
A7
X
Control mode
as per deliv-
ered condition
Programming
unit faulty
Replace program-
ming unit
Troubleshooting
Fault codes
(cont.)
5692 843 GB