56
4.
Select group of the required coding
address with
V
/
v
. For example,
"1" for group "General" (see following
section):
Confirm selected group with
OK
.
5.
Select coding address with
V
/
v
.
6.
Select value according to the follow-
ing tables with
V
/
v
and confirm with
OK
.
7. If you want to reset all codes to
their delivered condition:
Select
Ú
"
7
"
and confirm with
OK
.
When " " flashes, confirm with
OK
.
Note
This also resets codes from coding
level 1.
General/Group "1"
Select
"General"
for weather-compensated control units (see page 55).
Select
"1"
for constant temperature control units (see page 55).
Coding
Coding in the delivered condition
Possible change
00:1
System version 1:
One heating circuit with-
out mixer (A1), without
DHW heating
00:2
to
00:10
For system schemes, see
the following table:
Value
address
00: ...
System
version
Description
2
1
One heating circuit without mixer (heating circuit 1), with DHW
heating (code is adjusted automatically)
3
2
One heating circuit with mixer (heating circuit 2), without DHW
heating
4
2
One heating circuit with mixer (heating circuit 2), with DHW
heating
5
3
One heating circuit without mixer (heating circuit 1) and one
heating circuit with mixer (heating circuit 2), without DHW
heating (code is adjusted automatically)
6
3
One heating circuit without mixer (heating circuit 1) and one
heating circuit with mixer (heating circuit 2), with DHW heating
(code is adjusted automatically)
Code 2
Calling up coding level 2
(cont.)
5692 843 GB