71
Coding in the delivered condition
Possible change
0C:1
Delta T monitoring
switched ON.
No flow rate captured in
the collector circuit, or
flow rate too low.
0C:0
Delta T monitoring
switched OFF.
0d:1
Night circulation monitor-
ing switched ON.
Unintentional flow rate is
captured in the collector
circuit (e.g. at night).
0d:0
Night circulation monitor-
ing switched OFF.
0E:1
Calculation of solar yield
with Viessmann heat
transfer medium
0E:2
Calculation of solar yield
with water as heat transfer
medium (do not select as
operation is only possible
with Viessmann heat trans-
fer medium)
0E:0
Calculation of solar yield
switched OFF
0F:70
The flow rate in the col-
lector circuit at the maxi-
mum pump speed is set
to 7 l/min.
0F:1
to
0F:255
Flow rate in the collector
circuit adjustable from 0.1
to 25.5 l/min
10:0
Target temperature con-
trol switched OFF (see
coding address 11)
10:1
Target temperature control
switched ON
Code 2
Solar/Group "4"
(cont.)
5692 843 GB