96
Buffer cylinder
Parameter
Code
Delivered condition Commission-
ing
Maintenance/
service
Enable buffer cylinder/low loss header
7200
0
Temp in operating status fixed value for buf-
fer cyl
7202
500 (
≙
50 °C)
Hysteresis temperature heating buffer cylin-
der
7203
50 (
≙
5 K)
Max. temperature buffer cylinder
7204
600 (
≙
60 °C)
Stop optimisation heating buffer cylinder
7205
0
Temp limit op. status fixed value for buffer
cylinder
7208
500 (
≙
50 °C)
Stop hysteresis, heating water buffer cylin-
der
7209
0 (
≙
0 K)
Operating mode, fixed value only for heat
demand
720A
0
Temp in op. status. fixed value for coolant
buff cyl.
7220
200 (
≙
20 °C)
Stop hysteresis coolant buffer cylinder
7223
20 (
≙
2 K)
Min. temperature coolant buffer cylinder
722A
40 (
≙
4 °C)
Start hysteresis coolant buffer cylinder
722B
50 (
≙
5 °C)
Heating circuit 1
Parameter
Code
Factory setting
Commission-
ing
Maintenance/
service
Standard room temperature
2000
200 (
≙
20 °C)
Reduced room temperature
2001
160 (
≙
16 °C)
Remote control
2003
0
Room temperature control
2005
0
Heating curve level
2006
0 (
≙
0 K)
Heating curve slope
2007
6 (
≙
0.6)
Influence room temperature hook-up
200A
10
Room temperature hook-up
200B
0
Max. flow temperature heating circuit
200E
400 (
≙
40 °C)
Room temperature in party mode
2022
200 (
≙
20 °C)
Cooling
2030
0
Dew point monitor
2031
1
Min. flow temperature cooling
2033
200 (
≙
20 °C)
Influence room temperature hook-up cooling
circuit
2034
0
Hysteresis room temp cooling circuit
2037
10
Cooling curve level
2040
0
Cooling curve slope
2041
12
Commissioning/service reports
Control parameter report
(cont.)
6150148
Appendix