90
■
Fuse F1 is located on the mains terminal of the heat
pump control unit.
Fuse type:
–
6.3 A H (slow), 250 V~
–
Max. power loss
≤
2.5 W
■
Fuse F3 is located on the main PCB.
Fuse type:
–
2.0 A H (slow), 250 V~
–
Max. power loss
≤
2.5 W
■
The fuses for the fan and the refrigerant circuit con-
troller are located in the outdoor unit above the EEV
PCB.
1.
Switch OFF the power supply.
2.
Opening the wiring chamber.
3.
Check fuses. Replace if necessary.
Danger
Incorrect or improperly fitted fuses can lead
to an increased risk of fire.
■
Insert fuses without using any force. Posi-
tion fuses correctly.
■
Only use structurally identical types with
the same response characteristics.
Danger
Removing the fuse does
not switch the power
circuit to zero volt
. Contact with 'live' compo-
nents can lead to serious injury from electric cur-
rent.
Before working on the equipment, always
ensure that
the power circuit is also at zero
volt.
Maintenance
Checking the fuses
(cont.)
6150148
Maintenance