109
Type AWO/AWO-E/AWO-E-AC
201.A10
201.A13
201.A16
Outdoor unit dimensions
Total length
mm
546
546
546
Total width
mm
1109
1109
1109
Total height
mm
1377
1377
1377
Indoor unit dimensions
Total length
mm
370
370
370
Total width
mm
450
450
450
Total height
mm
880
880
880
Total weight
Outdoor unit
kg
153
153
153
Indoor unit
■
Type AWO
kg
40
40
40
■
Type AWO-E/AWO-E-AC
kg
41
41
41
Permissible operating pressure
, secondary
side
bar
3
3
3
MPa
0.3
0.3
0.3
Connections
(female thread)
Heating water flow
G
1
¼
1
¼
1
¼
Heating water return and DHW cylinder return
G
1
¼
1
¼
1
¼
DHW cylinder flow
G
1
¼
1
¼
1
¼
Secondary circuit flow
G
1
¼
1
¼
1
¼
Secondary circuit return
G
1
¼
1
¼
1
¼
Length of connection line between indoor
—
outdoor units
(Hydraulic connection set)
m
1 to 20
1 to 20
1 to 20
Sound power of outdoor unit
at rated heating output
(Measurements with reference to EN 12102/
EN ISO 9614-2)
Weighted total sound power level
■
At A7
±
3 K
/W55
±
5 K
(max.)
dB(A)
61
61
61
■
At A7
±
3 K
/W55
±
5 K
in night mode
dB(A)
55
55
55
Energy efficiency class
to EU Regulation no.
813/2013
Heating, average climatic conditions
■
Low temperature applications (W35)
A
+++
A
+++
A
+++
■
Medium temperature applications (W55)
A
++
A
++
A
++
Performance data
as per EU Regulation no.
813/2013 (average climatic conditions)
Low temperature applications (W35)
■
Energy efficiency
η
S
%
180
182
182
■
Rated heating output P
rated
kW
9.75
10.99
11.65
■
Seasonal coefficient of performance (SCOP)
4.58
4.64
4.62
Medium temperature applications (W55)
■
Energy efficiency
η
S
%
132
134
134
■
Rated heating output P
rated
kW
9.67
11.00
11.98
■
Seasonal coefficient of performance (SCOP)
3.37
3.42
3.42
Sound power level to ErP
Sound power level, outdoor unit
dB(A)
56
56
56
Specification
Specification
(cont.)
6150148
Appendix