97
■
All
codes are accessible in coding
level 2.
■ Codes that have not been assigned a
function due to the heating system
equipment level or the setting of other
codes are not displayed.
■ The heating circuit without mixer is
labelled
"Heating circuit 1"
and the
heating circuits with mixer are labelled
"Heating circuit 2"
or
"Heating cir-
cuit 3"
.
If the heating circuits were individually
named, the selected name and
"HC1"
,
"HC2"
or
"HC3"
appears
instead.
1.
Press
OK
and
å
simultaneously
for approx. 4 s.
2.
Press
OK
and simultaneously for
approx. 4 s.
3. "Coding level 2"
4.
Select the required coding address
group:
■
"General"
■
"Boiler"
■
"DHW"
■
"Solar"
■
"Heating circuit 1/2/3"
■
"All codes std device"
In this group, all coding addresses
from coding level 1 (except coding
addresses from the
"Solar"
group)
are displayed in ascending order.
5.
Select coding address.
6.
Select value according to the follow-
ing tables and confirm with
OK
.
7. If you want to reset all codes to
their delivered condition:
Select
"Standard setting"
in
"Cod-
ing level 2"
.
Note
This also resets codes at coding level
1.
"General"
Select group
"General"
(see page 97).
Code 2
Calling up coding level 2
5773 238 GB
Service
Summary of Contents for B2UA
Page 10: ...10 13 14 15 Preparing for installation Preparing the installation cont 5773 238 GB ...
Page 11: ...11 16 Preparing for installation Preparing the installation cont 5773 238 GB Installation ...
Page 12: ...12 sF 17 19 21 20 18 Preparing for installation Preparing the installation cont 5773 238 GB ...
Page 14: ...14 27 26 25 Preparing for installation Preparing the installation cont 5773 238 GB ...
Page 41: ...41 2x 1 4 2 3 5 Installation sequence Fitting the front panels 5773 238 GB Installation ...
Page 199: ...199 5773 238 GB ...