7
The range of functions can be extended with additional
components and accessories.
Intended use presupposes that a fixed installation in
conjunction with permissible, system-specific compo-
nents has been carried out.
Commercial or industrial usage for a purpose other
than central heating/cooling or DHW heating shall be
deemed inappropriate.
Incorrect usage or operation of the appliance (e.g. the
appliance being opened by the system user) is prohibi-
ted and will result in an exclusion of liability. Incorrect
usage also occurs if the components in the heating
system are modified from their intended function.
Note
The appliance is intended exclusively for domestic or
semi-domestic use, i.e. even users who have not had
any instruction are able to operate the appliance
safely.
Product information
Layout
Vitocal 222-S is a split air/water heat pump, comprising
1 indoor unit with integral DHW cylinder and 1 outdoor
unit.
Refrigerant circuit
All components of the refrigerant circuit including the
refrigerant circuit controller with an electronic expan-
sion valve are located in the external unit, except for
the condenser. Subject to operating conditions, com-
pressor output is matched via inverter control.
The internal and external units are connected to each
other hydraulically via the refrigerant lines.
Hydraulics
The internal unit is equipped with a high efficiency [HE]
circulation pump (secondary pump) which transports
the heated heating water into the secondary circuit.
The integral 3-way diverter valve for "Heating/DHW"
changes over between central heating and DHW heat-
ing.
Central heating
The heat pump can supply up to 2 heating circuits: 1
heating circuit without mixer and 1 heating circuit with
mixer. The mixer extension kit (accessories) is
required to switch the mixer.
Central cooling
The Vitocal 222-S, type AWT-AC can be used for cen-
tral cooling.
Central cooling results either through a heating/cooling
circuit or via a separate cooling circuit. For this, the
refrigerant circuit is reversed and heat is extracted
from the cooling circuit.
Heat pump control unit
The entire heating system is monitored and controlled
by the integral heat pump control unit Vitotronic 200,
type WO1C.
Type overview
Vitocal 222-S, type
AWT
AWT-AC
221.A 221.B 221.A 221.B
Central heating
X
X
X
X
DHW heating
X
X
X
X
Central cooling
—
—
X
X
Integral instantane-
ous heating water
heater
X
X
X
X
Outdoor unit power
supply
230 V~ 400 V~ 230 V~ 400 V~
Information
Intended use
(cont.)
5776 028 GB
Information
Summary of Contents for AWT 221.A04
Page 77: ...77 Maintenance Checking the fuses cont 5776 028 GB Maintenance...
Page 87: ...87 Indoor unit parts lists Indoor unit hydraulics cont 5776 028 GB Components...
Page 90: ...90 Indoor unit parts lists Indoor unit cylinder cont 5776 028 GB Components...
Page 137: ...137 Wind direction 11 Wind loads 11 Keyword index Keyword index cont 5776 028 GB...
Page 138: ...138 5776 028 GB...
Page 139: ...139 5776 028 GB...