128
Type AWT/AWT-AC
221.B10
221.B13
221.B16
Sound power of external unit
at rated
heating output
(measurements with reference to EN 12102/
EN ISO 9614-2)
Weighted total sound power level
■
At A7
±
3 K
/W55
±
5 K
dB(A)
61
65
69
■
At A7
±
3 K
/W55
±
5 K
in night mode dB(A)
60
60
60
Energy efficiency class
to EU
Regulation no. 811/2013
Heating, average climatic condi-
tions
■
Low temperature applications
(W35)
A
++
A
++
A
++
■
Medium temperature applica-
tions (W55)
A
++
A
++
A
++
DHW heating
■
Draw-off profile XL
A
A
A
Specification
Specification
(cont.)
5776 028 GB
Appendix
Summary of Contents for AWT 221.A04
Page 77: ...77 Maintenance Checking the fuses cont 5776 028 GB Maintenance...
Page 87: ...87 Indoor unit parts lists Indoor unit hydraulics cont 5776 028 GB Components...
Page 90: ...90 Indoor unit parts lists Indoor unit cylinder cont 5776 028 GB Components...
Page 137: ...137 Wind direction 11 Wind loads 11 Keyword index Keyword index cont 5776 028 GB...
Page 138: ...138 5776 028 GB...