47
Mains power supply in conjunction with on-site power consumption
Without power-OFF
kWh
G
F
L
kWh
F
L
E
kWh
N
E1E2
D /D
L1 L1 L2 L2 L3 L3
C
A
M
N
N
A
~~
=
D
H
K
M
F
B
F
Fig. 46
A
Heat pump
B
Additional consumers (of power generated on site)
in the household
C
Electricity meter
D
Inverter
E
Isolator for the PV system
F
Terminal
G
Double-tariff meter (for special tariff for heat pump)
Not
permissible in conjunction with PV systems for
on-site power consumption
H
Bi-directional meter (for PV systems to consume
power on site):
Energy taken from power supply utility and energy
fed into power supply utility
K
Meter with reverse block:
For energy generated by PV system
L
Isolator for the domestic power supply connection
(distribution panel)
M
Distribution panel
N
Domestic distribution box
Smart Grid
■
The Smart Grid functions are switched via both PSU
floating contacts.
■
Both floating contacts are connected to the
EA1 extension in accordance with Fig. 47.
Installation sequence
Power supply
(cont.)
5776 028 GB
Installation
Summary of Contents for AWT 221.A04
Page 77: ...77 Maintenance Checking the fuses cont 5776 028 GB Maintenance...
Page 87: ...87 Indoor unit parts lists Indoor unit hydraulics cont 5776 028 GB Components...
Page 90: ...90 Indoor unit parts lists Indoor unit cylinder cont 5776 028 GB Components...
Page 137: ...137 Wind direction 11 Wind loads 11 Keyword index Keyword index cont 5776 028 GB...
Page 138: ...138 5776 028 GB...
Page 139: ...139 5776 028 GB...