36
Plug
sYS
Terminals
Function
Explanation
212.3
DHW circulation pump
Connection values
■
Output: 50 W
■
Voltage: 230 V~
■
Max. switching current: 4(2) A
212.4
3-way diverter valve for heating water
buffer cylinder bypass or heat pump
in the case of dual alternative mode
Connection values
■
Output: 130 W
■
Voltage: 230 V~
■
Max. switching current: 4(2) A
Connecting a temperature limiter as a maximum temperature limiter for underfloor heating
Connecting a general temperature limiter
B
M
1~
C
B
X2.N
?
A
X1.
Fig. 27
Connecting the temperature limiter, part no. 7151 728,
7151 729
B
M
1~
C
B
sÖ
X2.N
?
A
X1.
Fig. 28
Heating circuit without mixer A1/HC1
Connection
A
to
control unit
Circulation pump
C
■
Without heating water buffer cylinder
211.2
Secondary pump
■
With heating water buffer cylinder
212.2
Heating circuit pump A1/HC1
Connecting the temperature limiter, part no. 7151 728,
7151 729
B
to mixer extension kit
M
1~
C
B
A
sÖ
sÖ
Fig. 29
A
Connect plug
sÖ
to mixer extension kit
B
Temperature limiter
C
Heating circuit pump for heating circuit with mixer
Installation sequence
Electrical connection
(cont.)
5776 028 GB
Installation
Summary of Contents for AWT 221.A04
Page 77: ...77 Maintenance Checking the fuses cont 5776 028 GB Maintenance...
Page 87: ...87 Indoor unit parts lists Indoor unit hydraulics cont 5776 028 GB Components...
Page 90: ...90 Indoor unit parts lists Indoor unit cylinder cont 5776 028 GB Components...
Page 137: ...137 Wind direction 11 Wind loads 11 Keyword index Keyword index cont 5776 028 GB...
Page 138: ...138 5776 028 GB...
Page 139: ...139 5776 028 GB...