36
A
Wiring chamber, external unit: See page 33.
B
Power supply 230 V/50 Hz
Type AWB/AWB-AC
201.B04
201.B05
201.B07
201.B10
201.B13
Cable cross-section
3 x 2.5 mm
2
3 x 2.5 mm
2
3 x 2.5 mm
2
3 x 2.5 mm
2
3 x 4.0 mm
2
Max. cable length
29 m
25 m
25 m
20 m
20 m
or
or
Cable cross-section
—
—
—
3 x 4.0 mm
2
3 x 6.0 mm
2
Max. cable length
—
—
—
32 m
30 m
Fuse protection
B20A
B20A
B20A
B20A
B32A
External unit power supply 400 V~
!
Please note
Incorrect phase sequence can cause damage to
the appliance.
Make the compressor power supply
only
in the
phase sequence specified (see terminals) with a
clockwise
rotating field.
Type AWB/AWB-AC 201.C10 to C16
?
N L
?
N L3
C2 C1
B
?
N
L1
A
L2L1
L2
L3
Fig. 36
A
Wiring chamber, external unit: See page 33.
B
Power supply 400 V/50 Hz
Type AWB/AWB-AC
201.C10
201.C13
201.C16
Cable cross-section
5 x 2.5 mm
2
5 x 2.5 mm
2
5 x 2.5 mm
2
Max. cable length
30 m
30 m
30 m
Fuse protection
B16A
B16A
B16A
Installation sequence
Power supply
(cont.)
5700 542 GB