The flush valve comprises a siphon / odour trap. No addi-
tional siphon is required outside of the flush valve.
NOTICE!
The dimension of the wastewater conduits must comply
with the specifications of DIN 1986-100.
During a water exchange, a flow switch checks whether water is dis-
charged in the proper manner.
The flow switch also signals improper
flowthrough without flushing command, e.g. in case of a defective
magnet valve etc.
The following functions can be set by means of floating contacts, see
n
Message: Operating / fault
n
Message: Water exchange ongoing
n
Message: Backflow
n
Message: Active valve runs / setting of flowthrough volumes
mA
Connections
4
Standby
8
1 valve
12
2 valves
16
3 valves
20
4 valves
Flowthrough monitoring
Terminals for external sensor
Product information
Flush valve universal
14 from 62