Press down the locks at the side one after the other, and push up.
Pull the top apart.
Unscrew the strain clamp and push on the connection pipeline.
Push the top into the connection pipeline.
Connect the leads to the terminals.
n
N = blue
n
L = brown or black
You do not need a PE conductor.
Combine the halves of the connector.
Hand-tighten the strain clamp.
Return the connector to the power pack.
ð
You have connected the mains plug.
See
Fig. 6 - Connecting the external sensor to position 8.
For connecting the sensor outputs and inputs, use lines with an external
diameter of max. 13 mm (cable inlet 1) or max. 10 mm (cable inlet 2).
We recommend to use shielded lines for signal transmission.
Recommended line types:
n
Cable inlet 1: 4 x 2 x 0.5 mm
2
n
Cable inlet 2: 2 x 2 x 0.5 mm
2
The maximum length of the line is 50 m for 2 x 0.5 mm
2
.
Connecting the external sensor
Handling
Flush valve universal