22
•
Programming
XX091-04-01 Rev 104 AurorAcorD
(alarms activate when the TTL logic state goes low (0 volts)). To set contacts individually, proceed to the
next step.
7. Select In/Out Contacts from the Alarm Contacts screen to define each contact individually.
8. Define each alarm connected to the 37-pin alarm connector as an input to the AurorAcorD or as an output
from the AurorAcorD, using the definitions in the step above for normally open/closed and active high/low.
9. If you have not already defined motion processing, you may do so from the Alarm Inputs screen. Refer to
the Motion Detection section of this manual.
10. Enable or disable receiver alarms from the Receiver Alarms screen. Only enabled alarms will be
processed by the AurorAcorD.
11. Return to the Alarm Inputs screen and select Video Loss. To process alarms produced by a loss of video
from the camera, enable them in the Enable/Disable Video Loss screen.
12. Select Momentary/Latching Video Loss from the Video Loss screen and define each alarm as momentary
or latching.
Screen Field
Choices
Default
Enable/Disable Contacts
Alarm “X”
Enabled, Disabled
Enabled
In/Normally
Open
In/Normally Closed
Out/Active High
Out/Active Low
In/Normally
Open
Motion Setup
Refer to Motion Detection chapter.
Receiver Alarms
Receiver “X” Alarm
Enabled, Disabled
Enabled
Enable/Disable Video Loss
Camera “X” Video Loss
Enabled, Disabled
Enabled
Momentary/Latch Video
Loss
Camera “X” Video Loss
Momentary, Latch
Momentary
Alarm Outputs
Perform the following procedure to define alarm processing for alarm outputs.
1. Access the Alarm Outputs screen, referring to the menu path below.
1 Alarm Contacts
2 Alarm Buzzer: Disabled
3 Alarm Relay: On Any Alarm
ALARM OUTPUTS
to Choose. to Go Back.
or 1-16 to Select.
1 Enable/Disable Contacts
2 Momentary/Latch Contacts
3 In/Out Contacts
4 Disable All Alrm Contacts
5 Set all to In/Norm Open
6 Set all to In/Norm Clsd
7 Set all to Out/Actv Low
8 Set all to Out/Actv Hi
ALARM CONTACTS
to Choose. to Go Back.
or 1-16 to Select.
1 Alarm Inputs
2 Alarm Outputs
3 Alarm Display
4 Alarm Auto Acknowledge
5 Alarm On/Off Actions
6 Use Alarm Defaults
ALARM SETUP
to Choose. to Go Back.
or 1-16 to Select.
1 Alarm 1: Enabled
2 Alarm 2: Enabled
3 Alarm 3: Enabled
4 Alarm 4: Enabled
5 Alarm 5: Enabled
6 Alarm 6: Enabled
7 Alarm 7: Enabled
Alarm 8: Disabled
ENABLE/DISABLE CONTACTS
to Choose. to Go Back.
or 1-16 to Select.
1 Alarm 1: Latch
2 Alarm 2: Momentary
3 Alarm 3: Latch
4 Alarm 4: Latch
5 Alarm 5: Latch
6 Alarm 6: Latch
7 Alarm 7: Latch
Alarm 8: Momentary
MOMENTARY/LATCH CONTACTS
to Choose. to Go Back.
or 1-16 to Select.
1 Alarm 1: Out/Actv Hi
2 Alarm 2: In/Norm Clsd
3 Alarm 3: Out/Actv Low
4 Alarm 4: In/Norm Open
5 Alarm 5: In/Norm Open
6 Alarm 6: In/Norm Open
7 Alarm 7: In/Norm Open
Alarm 8: In/Norm Open
IN/OUT CONTACTS
to Choose. to Go Back.
or 1-16 to Select.
1 Display Setup
2 Camera Setup
3 Alarm Setup
4 Serial Port Setup
5 Time/Date Setup
6 Record/Playback Setup
7 System Setup
8 Disk Functions
MAIN MENU
to Choose. to Go Back.
or 1-16 to Select.
2. Each of the sixteen alarm devices connected to the 37-pin alarm connector may be defined as an input to
the AurorAcorD or as an output from the AurorAcorD. If you defined the contacts as input or output in the