8
DMV-100 Rotor Creep and Speed Detector - Installation Manual
2.1.1 Supplies needed
•
clean dry cloth
•
fine sandpaper (with non metallic particles)
•
a sensor installation kit including:
- glue (Loctite 330) and its activator (Loctite 7387)
or equivalent
- silicone (3145RTV) or equivalent
Sensor installation kit, sandpaper and cleaning rags
2.2 Positioning the air gap sensor
•
The air gap sensor must be placed beneath the
second ventilation hole. When the generator is in
rotation, the whole surface of the sensor must
face in parallel the flat portion of the moving rotor
poles.
•
The flat portion of a rotor pole is the laminated
steel core or solid steel body, without the plates
for mounting the pole to the rotor rim.
Sensor beneath second ventilation hole and facing flat portion of rotor