20
DMV-100 Rotor Creep and Speed Detector - Installation Manual
3.2.3 Silicone application
Caution
•
DO NOT APPLY SILICONE IN HYDROGEN-COOLED LOCATIONS.
•
When applying silicone, keep the detection surface of the sensor clean and free of silicone.
1. Cover the sensor’s integral cable with
silicone, from the top of the sensor to the
edge of the protective tubing.
To prevent cable deterioration, and dust and
debris from entering, apply silicone inside the
tubing to form a plug.
Figure 18 : Application of silicone
Summary of Contents for DMV-100
Page 1: ...DMV 100 Rotor Creep and Speed Detector Installation Manual...
Page 6: ...6 DMV 100 Rotor Creep and Speed Detector Installation Manual...
Page 10: ...10 DMV 100 Rotor Creep and Speed Detector Installation Manual...
Page 50: ...50 DMV 100 Rotor Creep and Speed Detector Installation Manual...