14
DMV-100 Rotor Creep and Speed Detector - Installation Manual
3.1.1 Supplies needed
3.1.2 Tools needed
•
assorted drill bits and taps
•
heat gun
•
cutters or saw for protective tubing
•
fish tape
•
standard wrench set
•
assorted screwdrivers
3.2 Step by step installation of the triaxial extension cable
3.2.1 On site preparation
Determine the run of the flexible conduit, from the location of the elbow assembly, on top of the stator frame,
to the enclosure. Always keep in mind the length of the triaxial extension cable.
Warning - Danger
Caution
Triaxial extension cables must be installed on the stator frame or a grounded surface to avoid
disrupting the equipotential, and prevent the formation of surface partial discharges and arcing.
•
triaxial extension cable installation kit,
comprised of:
- two (2) lengths of protective tubing 1/2 x 24”
- one (1) 3/4” watertight connector
- one (1) 90
°
3/8” elbow
- one (1) 3/4” to 3/4” coupling
- one (1) 3/4” to 1/2” reducer
- one (1) piece of 3/8” heat-shrinkable tubing
- three (3) hex screws 1/4-20 x 5/8
- three (3) metric hex screws M6-1,00 x 16mm
- three (3) 1/4” flat washer
- three (3) 1/4” spring lock washer
- two (2) 3/8” cable clamps for protective tubing
- one (1) 1” cable clamp for elbow assembly
•
flexible conduit (not supplied)
Figure 6 : Installation kit for one air gap sensor
Summary of Contents for DMV-100
Page 1: ...DMV 100 Rotor Creep and Speed Detector Installation Manual...
Page 6: ...6 DMV 100 Rotor Creep and Speed Detector Installation Manual...
Page 10: ...10 DMV 100 Rotor Creep and Speed Detector Installation Manual...
Page 50: ...50 DMV 100 Rotor Creep and Speed Detector Installation Manual...