22
OLS-85
3 G
ETTING
S
TARTED
C
ONNECTING
OPTICAL
CABLES
The OLS-85 connector type must match the cable connector
type:
• PC: BN 2305/01/11
• APC: BN 2305/21/26/31/36/66
The PC/APC versions are easily identified by the colors of the
name labels on the front:
• PC = blue
• APC = green
Notes:
Only single mode fibers (SMF) may be connected to the
OLS-85.To mount the JAE test adapter:
√
The optical connectors are properly cleaned (see
“Cleaning the
test port” on page 53
).
1.
Open the head cover and remove the protective cap (if still
mounted).
2.
Place the test adapter vertically on the optical connector with
the locking lever open.
3.
Close the locking lever once the test adapter is firmly seated.
You will hear the locking mechanism click.
4.
Repeat the procedure if the instrument is equipped with two
ports.
5.
Fit the fiber optic cable to the test adapter or close the head
cover.
Fig. 8
Mounting the JAE test adapter