84
OLS-85
10 S
PECIFICATIONS
OLS-85
SPECIFICATIONS
Output power range
1
Single port instruments
Dual port instruments
Signal stability
2
Modes
3
1 CW signal, T = 23 °C ±3 K, including connector, depending on quality of
connector applied to the OLS
2 wavelengths instruments
Laser (CW)
Laser (Modulated, Auto
λ
)
-3.00 to 0.00 dBm (± 1 dB)
-6.00 to -3.00 dBm (± 1 dB)
3 & 4 wavelengths instruments
Laser (CW)
Laser (Modulated, Auto
λ
)
-6.00 to -3.00 dBm (± 1 dB)
-9.00 to -6.00 dBm (± 1 dB)
SM port
Laser (CW)
Laser (Modulated, Auto
λ
)
-3.00 to 0.00 dBm (± 1 dB)
-6.00 to -3.00 dBm (± 1 dB)
MM port
LED (CW)
LED (Modulated, Auto
λ
)
-23.00 to -20.00 dBm
-26.00 to -23.00 dBm
2 At ambient temperature range -10 °C to +55 °C,
Δ
T = ±0.3 K
Short term
± 0.02 dB (within 15 min.)
Long term
± 0.20 dB (within 8 h)
3 Signal coding for automatic power meter wavelength detection. Works only
with Viavi power meters e.g. OLP-85
Continuous wave (CW), Modulated (270 Hz,1 kHz, 2 kHz), Auto
λ
Summary of Contents for SmartClass Fiber OLS-85
Page 1: ...SmartClass Fiber OLS 85 User s Guide BN 2313 98 21 2016 01 English ...
Page 92: ...92 OLS 85 ROHS ...
Page 93: ......