70
OLS-85
9 R
EMOTE
C
ONTROL
C
OMMANDS
:OVRL:SHOW
<BOOLEAN>
Displays or hides the overlay for a tested image.
Default:
TRUE
:OVRL:SHOW?
Returns TRUE if the overlay for a tested image is displayed.
Response type:
<BOOLEAN>
See :OVERL:SHOW command for more information.
:STOR:AUTO:INCR
:ENAB <BOOLEAN>
Enables the automatic increment feature.
Default:
TRUE
:STOR:AUTO:INCR
:ENAB?
Returns TRUE if the automatic increment feature is enabled.
Response type:
<BOOLEAN>
See :STOR:AUTO:INCR:ENAB command for more information.
:STOR:AUTO:INCR
:IDX <NR1>
Sets the start index for the automatic increment feature.
Valid range:
1 to maximum integer
Default:
1
:STOR:AUTO:INCR
:IDX?
Returns the current index for the automatic increment feature.
Response type:
<NR1>
See :STOR:AUTO:INCR:IDX command for more information.
:STOR:AUTO:INCR
:PRFX <STRING>
Sets the prefix for the automatic increment feature.
:STOR:AUTO:INCR
:PRFX?
Returns the prefix for the automatic increment feature.
Response type:
<STRING>
See :STOR:AUTO:INCR:PRFX command for more information.
:STOR:AVLB?
Returns whether the application can or cannot store measurements.
:STOR:GRP:NAME
<STRING>
Sets the selected storage group name.
:STOR:GRP:NAME?
Returns the name of the currently selected storage group.
Response Type:
<STRING>
See :STOR:GPR:NAME command for more information.
Command string
Parameter type / Response type / Unit / Info
Summary of Contents for SmartClass Fiber OLS-85