6.3.2 Time schedule
Each parameter set, see chapter 6.3.1, owns a time schedule, which determines during which
times the settings of the parameter set are used by the viasis for the measurement, display and
possible extensions
Time schedule:
1. LED display: on
2. Operation weekdays: Su,Mo,Tu,We,Th,Fr,Sa
3. Daily start time: 00:00
4. Daily stop time: 00:00
5. Back
Your choice 1...5?
The values of the time schedule shown above are the default values for parameter set 1 ex fac-
tory. All weekdays are operation weekdays and the daily operation time is the whole day in
case daily start and stop time are set to equal values. So parameter set 1 is valid the whole
week for each day. For the other parameter sets is by default no operation day defined, there-
fore they are deactivated.
In time periods not covered by the
time schedules, no measurements
and self evident no display opera-
tion will happen. The viasis is in a
low power energy saving mode,
without active radar and the viasis
will be “awaked” only at the next
valid time schedule time entry.
If the operation time of two or more
parameter sets overlap, always the
parameters of the lowest number
parameter set get valid.
In viagraph the time schedules of all
parameter sets are concentrated in
the input windows „
Scheduling“
,
which gets visible by activation of
the menus
Tools – Parameter sets –
on
, see illustration 42 and illustration 43.
6.3.2.1 Time schedule – Led display
This option permits a hidden measurement and storage of vehicle speeds without a visible out-
put on the numeric LED display for the vehicle driver. This function can be also realized if the
minimal and the maximal displayed speed parameters are set to equal values, see also 6.3.4.2.
Illustration 43: Time schedule