5 Start-up with the viasis
5.1 Mounting and Fixation
The viasis must be mounted
orthogonal to the road
and stable in a height of 2 meters till 4
meters below the housing edge, see . First mount the system and finally insert the battery.
Illustration 1: Vertical orientation
Following items must be observed:
Another mounting height or a strong inclination of the housing (exceeding 90° ± 8°) may
influence the distance range of the vehicle detection and the accuracy of the displayed speed
values.
The radar detector in the viasis needs „free sight“ on the measured vehicles. Avoid a mount-
ing behind trees, poles, high parking vehicles and so on.
The system shall not be used in the range of road turns and bends. Otherwise too low meas-
ured speeds can be the result.
For the fixation of the viasis at pole clamps use the delivered M6 slide nuts. Pull two slide nuts
in each C-profile rail at the backside of the viasis housing. With 2 x 2 M6 screws (not deliv-
ered) the pole clamp is fixed at the slide nuts, respectively the profile rails.
We offer a solid and lockable pole fixation kit for the viasis, see annex list of equipment chap-
ter 10.1 and our website
www.viatraffic.de.
If there is no possibility to mount to already existing poles or if the system is used only in short
mobile campaigns, we also deliver a mobile tripod, see annex list of equipment, with a tele-
scope pole. If you use a mobile tripod you should be aware that you need to guard the system!