5.2.2 Crossing traffic
Diagonal crossing traffic passing the radar beam can lead to a disturbing speed value display.
By following measures you can reduce the detection distance range of the radar:
Decline the viasis housing vertically (see illustration 1) up to 8° towards ground.
Reduce the sensitivity of the radar receiver, see also chapter 6.3.7.
If both measures show no satisfying results there is nothing to do as to get away from the
crossing traffic.
5.3 Viasis MINI text panel
During the mounting the fixed text of the viasis MINI is folded in the visible upright position
by means of a movable flap board, see illustration 5.
If the flap board is open and upright both hinges are
fixed with rotatable hooks in this position, see also red
arrow in illustration 4.
The fixation hook is hanged into the slot
at the hinge and secured by tightening
the knurled nut above.
The closed flap board is attached to the housing
during transport by two hidden magnetic holders.
Attention: Don’t forget to tighten the
knurled nuts before you transport the
viasis MINI. Otherwise they may get
loose and lost together with the hooks.
Illustration 4: Fixation hook
Illustration 5: Open flap board
Illustration 6: viasis MINI flap board closed