Setpoints
View and
change
operational
setpoints
Spare
Parts List
Contains
spare
parts
available
on site
Event Log
Lists last 400
events and
alarms
View Only
Graphic Data Record
Displays average temperature from Sensors A and B, the
average dew point from Sensors A and B, the supply refrigerant
temperature and the supply refrigerant control point graphs;
Data is View Only;
Display scale is adjustable
View Network
Shows status of all
connected units;
View Only
Set Alarms
Allows user to
change
settings for
alarms
Sensor
Data
Shows
readings of
sensors;
View Only
Active
Alarms
Lists all
current
alarms;
View Only
Display Setup
Change
settings for
display:
language and
time
Total Run Hours
Records the run time of all components and
allows setting of limits on run time; View Only
XDIO
Displays readings
for the individual
smart modules;
View Only
Service
Contacts
Contains key
contact
information
for service
Table 7.1 Liebert iCOM User Menu icons
7.3.2 Liebert iCOM Service Menu Icons and Legend
Service menus allow customized settings for site operations. Service Menu screens employ a codingthat
begins in “S” and is followed by parameters and information, such as settings.
Setpoint
s
View and change
operational
setpoints
Unit Diary
Shows all program
changes and
maintenance
performed,
Maintenance/
Wellness Settings
Shows all maintenance
records, calculates next
maintenance date
Diagnostics/
Service Mode
Enter Diagnostics/
Service Mode for troubleshooting and repair
Set Alarms
Change settings
for alarms
Sensor
Calibration/Setup
Setup and
calibrate
sensors for
site
Network
Setup or alter network
setting.
Options Setup
Enter specific settings for
various options
Smart Module
Setup of alarms and events. Set temperature limits
for supply and return sensors. Label smart
modules, view firmware version.
Service Contacts
Contains key
contact
information for
service
Table 7.2 Liebert iCOM Service Menu icons
7.4 Liebert XDC Alarms Descriptions
NOTE: Alarms
must be acknowledged
before they can be reset. To acknowledge or silence an alarm,
press the ALARM key one time. This will silence the alarm; the red LED will remain illuminated until the
alarm is reset.
•
CALL SERVICE
—Activated when Customer Input 1 is configured for “Call Service” and 24VAC
is applied to the input. This alarm is reset when the 24VAC is removed.
•
COMP 1A HIGH PRESSURE
—Activated when the control senses a high head pressure signal
from Compressor 1A . This alarm will reset when the main power is cycled or the HP 1A Alarm
Code variable in the Service Diagnostics menu is reset to 0.
Vertiv
| Liebert® Xtreme Density™ System Design Manual |
157
Summary of Contents for Liebert XD Series
Page 1: ...Liebert Xtreme Density System Design Manual...
Page 18: ...Vertiv Liebert Xtreme Density System Design Manual 18 This page intentionally left blank...
Page 20: ...Vertiv Liebert Xtreme Density System Design Manual 20 This page intentionally left blank...
Page 66: ...Figure 4 2 Overall dimensions Vertiv Liebert Xtreme Density System Design Manual 66...
Page 88: ...Figure 4 21 Liebert XDV dimensions Vertiv Liebert Xtreme Density System Design Manual 88...
Page 152: ...Vertiv Liebert Xtreme Density System Design Manual 152 This page intentionally left blank...
Page 166: ...Figure 7 7 Modules on a single chain Vertiv Liebert Xtreme Density System Design Manual 166...
Page 167: ...Figure 7 8 Modules on two chains Vertiv Liebert Xtreme Density System Design Manual 167...
Page 182: ...Vertiv Liebert Xtreme Density System Design Manual 182 This page intentionally left blank...
Page 199: ......