Main Board Unit
4
-
6
Chapter 4: Board Installation
SBX IP 320 Installation Guide
Switch, LED, and Connector
Before programming the System, switch 1-4 should be ON and then power cycle OFF and ON
to initialize the default System database. Once the database has been initialized, switch 1-4
should be placed in the OFF position to protect the database.
After putting the SW2 lithium battery switch ON to protect the RAM/RTC data, install the
option boards to the MBU.
Note:
•
The SW2-DIP switch should be turned ON to protect the System database in case of
power failure.
•
As needed, replace the batteries with the same or equivalent type recommended by the
manufacturer; the System will not function normally if the battery is incorrectly replaced.
•
Dispose of used batteries according to manufacturer instructions and/or local government
regulations.
•
The 4th pole of SW1 should be OFF to protect the features being programmed in Admin
programming after the System power up and initialization.
Table 4-7
MJ3 Pin Assignment (LAN)
CONNECTOR
PIN NUMBER
NO
SIGNAL NAME
FUNCTION
4, 5, 7, 8
RESERVED
1
TX+
Transmit Data
2
TX-
Transmit Data
3
RX-
Receive Data
6
RX+
Receive Data
Table 4-8
SW1 Functions
SWITCH
FUNCTION
OFF
ON (DEFAULT)
1-1
Administration Programming Access
Disable
Enable
1-2
Command/Event Trace (Software Testing)
Enable
Disable
1-3
Simplified Message Desk Interface control
(SMDI - Voice Mail)
SMDI ON
SMDI OFF
1-4
Database Default on Power Up
Disable
Enable
Summary of Contents for SBX IP 320
Page 1: ...Installation Guide SBX IP 320 ...
Page 4: ......
Page 40: ...Expansion KSU Installation 3 22 Chapter 3 KSU Installation SBX IP 320 Installation Guide ...
Page 58: ...Other Board Installations 4 18 Chapter 4 Board Installation SBX IP 320 Installation Guide ...
Page 84: ...Basic Programming 6 16 Chapter 6 Starting the SBX IP 320 SBX IP 320 Installation Guide ...
Page 100: ...Starting S W Upgrade 8 8 Chapter 8 Software Upgrade SBX IP 320 Installation Guide ...
Page 142: ... Data Display Area 9 42 Chapter 9 Remote Diagnostics SBX IP 320 Installation Guide ...