VTK
‐
VS
‐
BA
‐
004e
‐
B
|
User
Manual
MDS
3200A
|
Cleaning
55
8.3
Cleaning
Methods
The
following
methods
are
available:
Pre
‐
purifying
Rinsing
with
a
purifying
agent
Total
disassembly
of
the
valve,
followed
by
fine
purification
8.3.1
Pre
‐
purifying
Pre
‐
purifying
consists
in
purging
the
system
with
compressed
air.
CAUTION!
(potential
liquid
spurts)
During
this
procedure,
liquid
droplets
may
be
expulsed!
Users
must
protect
themselves
correspondingly.
Step
1:
The
dispensing
process
must
be
completed.
The
valve
is
in
closed
position.
Do
NOT
switch
OFF
the
control
unit.
Step
2:
Separate
the
compressed
‐
air
connection.
The
pressure
must
be
reduced
to
0
bar.
Disconnect
the
PP
adapter
fitting
from
the
cartridge.
Step
3:
Replace
the
used
cartridge
by
a
new
one.
Step
4:
Reinstall
the
compressed
‐
air
as
follows:
Place
the
PP
adapter
fitting
on
the
cartridge.
Rotate
clockwise,
until
it
latches
in
place.
Connect
the
PVC
hose
with
the
KS4
‐
CK
‐
6
coupler
plug
to
a
compressed
‐
air
supply.
For
this
purpose
you
require
a
KD4
‐
1/2
‐
A
coupler
socket.
Activate
the
compressed
‐
air
supply.
Step
5:
Place
a
container
underneath
the
valve,
to
collect
any
liquid
dripping
out.
Step
6:
Initiate
the
purging
procedure
by
pressing
[F1]
.
Keep
the
[F1]
key
pressed
until
the
procedure
is
complete
and
no
more
liquid
flows
out
through
the
nozzle
unit.
INFORMATION!
(automatic
closing)
After
ca.
2
min
the
valve
closes
automatically,
in
order
to
protect
the
actuator.
Alternatively,
the
procedure
can
be
performed
by
the
RS
‐
232C
interface.
Use
the
commands
VALVE:UP
and
VALVE:DOWN
for
this
purpose.
Step
7:
Separate
the
compressed
‐
air
connection
and
remove
the
cartridge.
Step
8:
Make
sure
the
collected
liquid
in
the
container
is
disposed
of
according
to
local
regu
‐
lation.