VTK
‐
VS
‐
BA
‐
004e
‐
B
|
User
Manual
MDS
3200A
|
Initial Operation
31
5.4
The
Adjust
The
following
segments
explain
the
adjust.
The
description
assumes
you
are
controlling
the
adjustment
procedure
directly
via
MDC.
It
is
also
possible
to
do
it
remotely
via
the
RS
‐
232C
interface.
The
relevant
information
for
this
method
can
be
found
in
chapter
7.1.2.
5.4.1
Purpose
The
system
is
unable
to
perform
a
regular
repeatable
process,
if
the
nozzle
insert
is
not
properly
positioned
in
relation
to
the
tappet
prior
to
dispensing.
Therefore
you
have
to
per
‐
form
a
general
adjustment
procedure
(simply
called
“adjust”)
during
initial
operation
and
af
‐
ter
each
exchange
of
the
nozzle
unit.
This
is
especially
important
to
avoid
any
leakage
during
dispensing.
5.4.2
Procedure
CAUTION!
(cleaning
before
adjust)
The
system
has
to
be
cleaned
thoroughly
before
the
adjust.
The
presence
of
dirt
par
‐
ticles
jammed
between
the
tappet
surface
and
the
nozzle
insert
would
compromise
the
results.
Step
1:
First
unscrew
the
nozzle
unit
from
the
fluid
box.
Step
2:
Initiate
the
procedure
by
pressing
the
[adj]
key.
Step
3:
Use
tool
MDT
302
(or
alternatively
MDT
301,
if
necessary
for
spatial
reasons)
to
rotate
the
nozzle
unit
towards
the
fluid
box,
until
the
red
control
LED
is
lit.
The
in
‐
dicated
value
displayed
should
amount
to
1100
or
slightly
above.
IMPORTANT
NOTE!
(limit)
Maximum
admissible
display
value
is
1250,
otherwise
the
tappet
can
break
afterwards.
IMPORTANT
NOTE!
(careful
installation)
Screw
the
nozzle
unit
onto
the
fluid
box
carefully.
Avoid
tilting
the
nut
by
tilting
the
nozzle
unit.
This
procedure
requires
sufficient
concentration.
If
the
tappet
guidance
including
the
nozzle
insert
has
not
been
installed
correctly,
the
adjust
may
fail
(see
page
27).
Step
4:
Rotate
the
nozzle
unit
counterclockwise,
until
the
green
LED
is
lit.
The
displayed
value
should
be
in
the
range
between
1030
and
1040.
IMPORTANT
NOTE!
(unstable
values)
The
whole
procedure
has
to
be
repeated,
if
the
value
fluctuates
or
decreases
within
a
short
period
of
time
(ca.
5
sec)
,
starting
from
step
1.
Step
5:
At
the
end,
confirm
the
adjust
by
pressing
[enter]
.
INFORMATION!
(abort
procedure)
The
procedure
can
be
aborted
any
time
by
pressing
[esc]
.
After
the
adjust
the
green
lamp
dims
within
5
sec.
Summary of Contents for MDS 3000 Series
Page 1: ......
Page 58: ...VTK VS BA 004e B User Manual MDS 3200A Cleaning 58 8 3 4 Fine Purification of Components...
Page 72: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 72 13 2 Dimensional Drawing MDC 3200A...
Page 74: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 74 13 4 Connection Diagram PLC Interface...