General Instructions
8
2.3
Tools
The
following
tools
are
required
to
install
and
to
operate
the
MDS
3200A:
MDT
301
Universal
tool
(
Part
no.
1010208
)
MDT
302
Nozzle
adjusting
tool
(
Part
no.1009289
)
MDT
303
Nozzle
insert
changing
tool
(
Part
no.
1007083
)
MDT
304
Tool
for
squeezing
out
nozzle
inserts
(
Part
no.
1007085
)
MDT
310
Tappet
changing
tool
(
Part
no.
1008344
)
MDT
312
Tool
for
tappet
sealing
FX
(
Part
no.
1012825
)
Hexagon
socket
key
set
(
Part
no.
1012993
)
When
you
order
tools,
always
specify
the
part
number
of
the
required
item.
IMPORTANT
NOTE!
(No
foreign
tools)
Do
not
use
auxiliary
tools
or
foreign
products,
otherwise
damages
to
the
equipment
might
be
possible.
2.3.1
MDT
301
Universal
Tool
The
tool
MDT
301
consists
of
two
subcomponents
screwed
to
each
other:
“Sealmounter“
with
a
mandrel
to
insert
and
to
remove
the
tappet
seal
(1.)
“Adjustment
grip“
with
a
receptacle
for
the
nozzle
adjusting
nut
(2.)
Intended
Purpose:
1.
Fixing
and
removing
of
tappet
sealing
and
tappet
centering
piece
2.
It
may
also
be
used
to
execute
the
general
adjust
(alternatively
to
tool
MDT
302
described
below)
2.3.2
MDT
302
Nozzle
Adjusting
Tool
This
part
has
a
receptacle
for
the
nozzle
adjusting
nut
and
a
longer
lever
to
simplify
the
general
adjust.
It
can
also
be
used
in
combination
with
MDT
310,
if
a
better
leverage
is
needed.
Intended
Purpose:
1.
Performing
the
adjust
2.
Fixing
the
tighting
screw
to
the
fluid
box
3.
Changing
of
tappet
in
combination
with
MDT
310
2.3.3
MDT
303
Nozzle
Insert
Changing
Tool
The
MDT
303
is
required
for
the
exchange
of
the
nozzle
insert.
The
3
pins
of
the
MDT
303
grip
into
the
receptacle
bores
of
the
tappet
guidance
in
order
to
unscrew
the
tappet
guidance
from
the
nozzle
adjustment
nut.
Intended
Purpose:
1.
Screwing
apart
nozzle
adjusting
nut
and
tappet
guidance
when
changing
the
nozzle
insert
2.3.4
MDT
304
Nozzle
Insert
–
Squeezing
Out
Tool
The
diameters
of
the
end
pieces
of
tool
MDT
304
are
not
identical,
as
each
of
them
is
used
for
a
different
purpose:
Intended
Purpose:
1.
Squeezing
out
of
the
tappet
sealing
between
fluid
box
and
actuator
(1.)
2.
Detaching
the
nozzle
insert
from
the
tappet
guidance
(2.)