VTK
‐
VS
‐
BA
‐
004e
‐
B
|
User
Manual
MDS
3200A
|
Communication Interfaces
52
7.2.2
Remote
Adjust
7.2.2.1
Purpose
During
a
remote
adjust,
as
opposed
to
the
normal
procedure
(see
page
31)
,
the
system
is
operated
from
a
master
device
(e.g.
a
PC)
,
by
means
of
interfaces
(PLC,
RS
‐
232C).
The
func
‐
tion
itself
is
identical.
7.2.2.2
Advantages
The
remote
adjust
allows
for
total
control
of
an
MDC
3200A
integrated
in
a
machine,
since
dispensing
parameters
can
be
monitored
by
the
software
of
this
machine.
The
control
unit
can
be
built
in
with
permanent
key
lock.
Thus
the
modification
of
parameters
without
au
‐
thorization
can
be
prevented
in
the
machine
software.
7.2.2.3
Procedure
The
remote
adjust
has
to
be
performed
according
to
the
following
instructions:
INFORMATION!
(Displaying
remote
adjust)
In
the
course
of
the
entire
procedure,
both
adjust
LEDs
are
lit
simultaneously.
The
display
meanwhile
shows
“Remote
Adjust
is
running!”
For
transmission
of
the
orders
between
PC
and
control
unit,
both
of
the
interfaces
(RS
‐
232C
as
well
as
PLC
‐
interface)
are
used.
Step
1:
Send
the
command
“ADJUST:START“
to
the
control
unit
via
RS
‐
232C.
The
system
returns
the
message
“Unscrew
nozzle
press
enter“.
Step
2:
The
nozzle
unit
must
completely
be
detached,
so
that
the
tappet
becomes
visible.
Step
3:
In
order
to
confirm
step
2,
a
short
trigger
signal
(500
μ
s
–
80
ms)
must
be
sent
to
the
control
unit
–
via
PLC
‐
interface.
The
system
then
returns
the
current
“Adjust
Value”,
continuously
repeating
the
transmission
to
the
PC
in
intervals
of
500
ms
(via
RS
‐
232C)
.
Short
Trigger
signal:
5
V
or
24
V
(PIN2
+
PIN4
or
PIN3
+
PIN4
Input
signal
of
MDC
via
15
pin
Sub
‐
D)
Signal
length:
500
μ
s
–
80
ms
An
additional
command
to
update
the
adjust
value
on
the
screen
is
therefore
not
required.
Step
4:
Rotate
the
nozzle
unit
clockwise
towards
the
fluid
box,
until
the
value
displayed
on
PC
is
in
the
tolerance
range
(between
1020
and
1039)
.
If
desired,
you
can
also
watch
the
green
LED
on
the
control
unit.
Step
5:
Confirm
the
indicated
value
(e.g.
1035)
by
sending
a
short
trigger
signal
via
PLC
‐
interface,
as
described
above.
The
system
returns
the
following
response
via
RS
‐
232C:
1.
“Adjust
LED
Green“
=
The
adjust
has
successfully
been
completed
and
the
green
LED
is
lit.
Beyond
the
tolerance
range
(1020
‐
1039)
it
is
impossible
to
con
‐
firm
the
values.
In
these
inadmissible
ranges,
the
adjust
can
only
be
interrupted
by
sending
a
long
trigger
signal
(100
ms
–
200
ms)
to
the
control
unit
via
PLC
‐
interface.
The
system
returns
the
message
“Adjust
failed“
to
the
PC.
Long
Trigger
signal:
5
V
or
24
V
(PIN2
+
PIN4
or
PIN3
+
PIN4
Input
signal
of
MDC
via
15
pin
Sub
‐
D)
Signal
length:
100
ms
–
200
ms
Summary of Contents for MDS 3000 Series
Page 1: ......
Page 58: ...VTK VS BA 004e B User Manual MDS 3200A Cleaning 58 8 3 4 Fine Purification of Components...
Page 72: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 72 13 2 Dimensional Drawing MDC 3200A...
Page 74: ...VTK VS BA 004e B User Manual MDS 3200A Attachment 74 13 4 Connection Diagram PLC Interface...