VTK
‐
VS
‐
BA
‐
004e
‐
B
|
User
Manual
MDS
3200A
|
Communication Interfaces
47
Example:
Input:
VALVE:OPEN:
30,10,15,90,20,8
Result:
The
initiated
cycle
comprises
the
following
values:
Rising:
30
≙
3,0
ms
(ms
=
Milliseconds)
Open
Time:
10
≙
1,0
ms
Falling:
15
≙
0,15
ms
Needle
Lift:
90
%
Number
of
Pulses:
20
Delay:
8
≙
0,8
ms
Return:
OK
24.
VALVE:AOPEN:<Rising>,<Open
Time>,<Falling>,<Needle
Lift>,<Number
of
Pulses>,<Delay>
Description:
This
command
corresponds
to
instruction
no.
23
described
above.
In
this
case
however,
both
of
the
parameters
“Rising“
and
“Falling“
are
specified
in
steps
of
1/100
ms,
in
contrast
to
the
other
ramp
parameters
(1/10
ms)
.
Specified
values
must
be
integer
and
positive.
If
the
External
Mode
is
de
‐
sired,
instead
of
a
numerical
value
enter
“EXTERNAL”
for
“Open
Time”.
Also
in
this
case,
parameters
previously
entered
by
“TRIGGER:SET“
are
not
erased,
but
the
combination
remains
in
the
system
only
until
the
end
of
the
cycle.
Therefore,
if
the
user
does
not
wish
to
reenter
the
entire
com
‐
mand
several
times,
the
“TRIGGER:SET“
command
is
advantageous,
since
here
the
cycle
can
be
reactivated
simply
by
“VALVE:OPEN“,
as
desired.
Example:
Input:
VALVE:AOPEN:30,55,8,80,20,8
Result:
The
dispensing
cycle
includes
the
following
values:
Rising:
30
≙
0,3
ms
(ms
=
Milliseconds)
Open
Time:
55
≙
5,5
ms
Falling:
8
≙
0,08
ms
Needle
Lift:
80
%
Number
of
Pulses:
20
Delay:
8
≙
0,8
ms
Return:
OK
25.
VALVE:UP
Description:
The
valve
is
opened
until
it
receives
the
command
“VALVE:DOWN”.
Other
‐
wise
it
closes
automatically
after
2
min.
During
this
phase,
other
commands
are
ignored,
in
order
to
protect
the
valve.
Example:
Input:
VALVE:UP
Result:
The
valve
opens.
Return:
OK
26.
VALVE:DOWN
Description:
This
command,
closing
the
valve,
represents
the
only
instruction
accepted
in
a
“VALVE:UP“
phase.
In
other
situations,
it
remains
without
effect.
Example:
Input:
VALVE:DOWN
Result:
The
valve
is
closed.
Return:
OK