background image

®

ENDURO ICE/BEVERAGE DISPENSER

ED 250 BCP

Operator’s Manual

Release Date: June 7, 1999

Publication Number: 620916502OPR

Revision Date: October 15, 2002

Revision: A

Control Code: B

Visit the IMI Cornelius web site at www.cornelius.com for all your Literature needs.

Summary of Contents for ED 250 BCP

Page 1: ...SER ED 250 BCP Operator s Manual Release Date June 7 1999 Publication Number 620916502OPR Revision Date October 15 2002 Revision A Control Code B Visit the IMI Cornelius web site at www cornelius com for all your Literature needs ...

Page 2: ......

Page 3: ...perations 3 Ice Portion Control Set Up and Adjustment Procedure 3 MAINTENANCE 5 Daily or as required 5 Weekly or as required 5 Monthly 5 Cleaning Instructions 5 Dispenser 5 BEVERAGE SYSTEM 7 Cleaning 7 Cleaning Dispensing Valves 7 Sanitizing 7 Sanitize tank systems Post Mix and Pre Mix 7 Sanitize syrup lines B I B Systems 7 TROUBLESHOOTING 9 Trouble 9 Probable Cause 9 Remedy 9 WARRANTY 11 ...

Page 4: ...Publication Number 620916502OPR ii 2001 02 IMI Cornelius Inc ...

Page 5: ...OPR REMOVABLE STRAW HOLDER PANEL LID STRAW HOLDER BEVERAGE FAUCET ON OFF SWITCH ICE PORTION CONTROL MODULE MANUAL AUTO ICE TOGGLE SWITCH MANUAL ICE DISPENSE RED PUSH BUTTON SWITCH DRIP TRAY CUP REST LOWER ACCESS PANEL BEVERAGE FAUCETS 8 ICE AGITATOR RETAINER ICE BIN COVER FIGURE 1 PARTS IDENTIFICATION ...

Page 6: ...p rest against the faucet lever of the desired flavor Bever age will be dispensed automatically filling the cup and shutting off A delay feature is provided in the fau cet controller to top of the drink after shut off CAUTION Use caution to avoid spilling ice when filling dispenser Clean up immediately any spilled ice from filling or operating the unit To prevent contamination of ice the lid must ...

Page 7: ...te is replaced unit will automatically return to normal operation after one minute or INCREASE and DECREASE can simultaneously pressed 3 times Light Color Explanation Actions That Can Be Taken Step 1 Fill the Ice Chute Yellow Flashing Chute Agi tation Refill Time To enter Agitation Adjustment Mode simultaneously press INCREASE and DECREASE three times then press and hold INCREASE and DECREASE for ...

Page 8: ... size 5 millisecond per pulse NOTE Make sure the light blinks as the buttons are pressed The light will flash green for 5 sec onds While the green light is flash ing the ice portion can be tested by pressing the CUP SIZE again To exit Portion Adjustment Mode simultaneously press INCREASE and DECREASE two times Step 3 If desired set the extra ice portion adjustment Red Extra Ice Portion Adjustment ...

Page 9: ...ith clean water and allow solution to run down the drain C Wash cup rest with soap solution and rinse in clean water Install the cup rest into the drip tray D Clean all exterior surfaces with soap solution and rinse in clean water 2 CLEANING INTERIOR SURFACES CAUTION When pouring liquid into the hopper do not exceed the rate of 1 2 gallon per minute CAUTION It will be necessary to have electrical ...

Page 10: ...e sure that the retainer is secured tightly turn clockwise to screw in place G Clean and sanitize the ice chute as described below 1 Remove the ice chute cover snap fit by spreading the sides apart slightly to disengage the tabs in the cover from the ice chute and sliding down to remove the cover The ice chute rear half and the ice gate are now exposed for cleaning 2 Remove the black plastic acces...

Page 11: ...apply one of the product tubes to the cleaning tank Operate the appropriate valve until liquid dispensed is free of any syrup 7 Disconnect cleaning tank and hook up sanitizing tank to syrup line and CO2 system 8 Energize beverage faucet until chlorine sanitizing solution is dispensed through the faucet Flush at least two 2 cups of liquid to insure that the sanitizing solution has filled the entire...

Page 12: ...fteen 15 minutes 8 Remove the nozzle and syrup diffuser from each valve and clean them in a soap solution Rinse with clean water and reassemble the nozzle and syrup diffuser to the valve 9 Remove the sanitizing fittings from the B I B disconnects and connect the disconnects to the appro priate B I B container Operate the valves until all sanitizer has been flushed from the system and syrup is flow...

Page 13: ...ms consult ice maker manual D Improper use of flaked ice D Replaced flaked ice with cube style ice see page 2 Unit Description BEVERAGES DO NOT DIS PENSE A No 24 volt power to faucets A Check that beverage switch is on Check 24V transformers B No CO2 pressure B Check CO2 regulator Check CO2 tank pressure BEVERAGES TOO SWEET A Carbonator not working A Check carbonator B No CO2 pressure in carbonato...

Page 14: ...AL ICE DISPENSE PUSHBUTTON SWITCH A Manual Auto toggle switch in Auto position A Move toggle switch to Manual position B Insufficient or no CO2 supply to dis penser B Restore CO2 supply to dis penser C Defective 24VAC transformer C Replace Transformer D Defective manual override solenoid valve D Replace valve E Defective manual ice dispense push button switch E Replace switch F Defective agitator ...

Page 15: ...150 D FAX 55 21 593 1829 ENGLAND D TYTHING ROAD ALCESTER D WARWICKSHIRE B49 6 EU ENGLAND D 44 789 763 101 D FAX 44 789 763 644 FRANCE D 71 ROUTE DE ST DENIS D F 95170 DEUIL LA BARRE D PARIS FRANCE D 33 1 34 28 6200 D FAX 33 1 34 28 6201 GERMANY D CARL LEVERKUS STRASSE 15 D D 4018 LANGENFELD GERMANY D 49 2173 7930 D FAX 49 2173 77 438 GREECE D 488 MESSOGION AVENUE D AGIA PARASKEVI D 153 42 D ATHENS...

Page 16: ...Enduro Ice Beverage Dispenser Operator s Manual Publication Number 620916502OPR 12 2002 IMI Cornelius Inc ...

Page 17: ......

Page 18: ...IMI Cornelius Inc One Cornelius Place Anoka MN 55303 1592 U S A ...