EUROBLOC
GENERAL OVERHAUL INSTRUCTIONS
31/69
This document and the information contained herein, is the exclusive property of Verlinde S.A.S. and represents a non-public, confidential and proprietary trade secret that
may not be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of Verlinde S.A.S.
Copyright © (2013) Verlinde S.A.S. All rights reserved.
09/2016
8.3
Rope clamps
1. Rope
2. Rope drum
3. Rope clamps
4. Friction wraps (at least two full wraps)
Replace the rope clamps if:
Inspection method:
The inspection of rope clamps reveals any corrosion,
excessive wear, dents, cracks, or other damage.
Examine the threaded holes in the drum for wear.
Visual
TO ORDER: rope clamps: See Spare Part Catalogue
8.4
Wire rope
Replace the wire rope if:
Inspection method:
The inspection reveals broken wire(s), excessive wear,
localized reduction of the rope diameter, deformation,
local increase of the rope diameter, basket deformation,
protrusion of wire rope components (wire, strand, or
core), kinks, or bends.
Visual, measurements
TO ORDER: a wire rope: See Spare Part Catalogue
See more information on wire rope inspection, disassembly, and reassembly in “Service Manual for Hoist”.
8.5
Rope guide
The operational testing of the rope guide must be done before the hoist is lowered to the floor level.