OPERATION AUDIBLE SIGNAL VISUAL SIGNAL
NORMAL NONE STEADY GREEN
CO ALARM 4”BEEPS” STEADY RED
5 SECONDS OFF
PROPANE ALARM CONSTANT FLASHING RED
ALARM “BEEP” EVERY ALTERNATING
MALFUNCTION 30 SECONDS RED/GREEN
END OF LIFE ‘”BEEP” EVERY RED?RED
30 SECONDS GREEN/GREEN
FLASHING
WARM UP CYCLE NO WARM FLASHING GREEN
End of Life Signal—5 year Service Life
All 35 series models include an End of Life (EOL) signal indicating
the sensor has reached the end of it’s service life and you MUST
replace the alarm. The signal is the LED flashing RED RED
GREEN GREEN with a beep every 25-30 seconds. The EOL
Signal may be reset by pushing TEST/RESET button on the alarm.
This will reset the EOL Signal for a period of 72 hours (3 days )
for a total of 30 days. After 30 days the signal cannot be reset and
the alarm MUST be replaced. DO NOT DISCONNECT THE ALARM
UNTIL YOU HAVE A REPLACEMENT ALARM AVAIBALE TO
INSTALL.
LIMITATIONS OF CO AND GAS ALARMS
THIS ALARM WILL NOT WORK WITHOUT POWER
Some reasons for no alarm power are; a blown or missing fuse; broken
wire; a faulty wire connection or circuit breaker; a discharged battery; cut
lead wires, or improper supply (+) or ground (-) connections.