Mithos GSM Programmable Thermostat User Manual
network power supply
optimal GSM field coverage (100%)
number of the Mithos GSM card: 3331234567 (ND if not defined)
date: 01 July 2010
time:
14:55:23
“
(reg)
”, which in this case follows the measured internal probe temperature,
indicates which of the two probes (if both are present) will be regulated.
MANAGING THE ALARMS
The programmable thermostat can be configured to sent alarm text messages to
the numbers in the telephone book.
There are four alarm sources:
– minimum alarm if the measured temperature goes below a specified threshold
– maximum alarm if the measured temperature exceeds a specified threshold
– power supply alarm if there is a blackout
– external alarm in the case of a generic alarm on the digital input
For each alarm source, it is possible to specify the numbers in the telephone book
to which the text message should be sent.
The instrument is configured in the factory to send alarms to the first
number in the telephone book in the following cases:
– power supply failure and restoration
– temperature measured by the internal probe below 5 °C
– closed digital input status alarm (with 10 second delay)
The following commands can be used to change this configuration.
Defining alarm recipients
It is possible to specify message recipients for each alarm source.
The command syntax is:
INVIO ALLARME MINIMA
[recipient] …[recipient]
INVIO ALLARME MASSIMA
[recipient] …[recipient]
INVIO ALLARME ESTERNO
[recipient] …[recipient]
INVIO ALLARME ALIMENTAZIONE
[recipient] …[recipient]