- 38 -
Mithos GSM Programmable Thermostat User Manual
IMPOSTA ALLARME CONTATTO
restores the current configuration of the input
alarm
Some
examples:
IMPOSTA ALLARME CONTATTO APERTO 10 digital input alarm if the
programmable thermostat input
has an open status for at least 10
seconds
IMPOSTA ALLARME CONTATTO CHIUSO 30 digital input alarm if the
programmable thermostat input has
closed status for at least 30 seconds
Notes:
the alarm return is immediate in correspondence with the contact
status change.
Defining the digital alarm text
Using the command TESTO ALLARME ESTERNO, it is possible to specify the text of
the message sent to the numbers in the telephone book following an alarm on the
digital input.
The command syntax is:
TESTO ALLARME ESTERNO
[text] where
[text] text of maximum 24 characters (spaces included)
For
example:
TESTO ALLARME ESTERNO boiler shutdown alarm in this case, if an alarm
occurs on the input, the text
“boiler shutdown alarm”
will be sent to the specified
numbers.
Definition of the temperature threshold exceeded alarm
Using the commands IMPOSTA ALLARME MASSIMA and IMPOSTA ALLARME
MINIMA, a maximum or minimum threshold can be set that if exceeded, generates
an alarm that is sent to the numbers specified in the telephone book.
The command syntax is:
IMPOSTA ALLARME MASSIMA
[probe] [threshold] [hysteresis] [delay]
IMPOSTA ALLARME MINIMA
[probe] [threshold] [hysteresis] [delay]