- 37 -
Mithos GSM Programmable Thermostat User Manual
where:
[recipient] indicates the number in the phone book to which the alarm is sent
Some
examples:
INVIO ALLARME ESTERNO 1 3 4 sends a text message to numbers 1, 3, 4 in the
telephone book if there is a digital input alarm
INVIO ALLARME MASSIMA 2 sends a text message to number 2 in the telephone
book in the case of a temperature threshold
exceeded alarm
INVIO ALLARME ALIMENTAZIONE 5 sends a text message to number 5 in the
telephone book in the case of a power supply
failure
If a recipient is not specified, the instrument responds with the list of numbers that
receive the alarm. For example:
INVIO
ALLARME
ESTERNO
ALLARME ESTERNO=1, 3, 4
Note: newly setting the alarm recipients will overwrite the previous setting,
therefore all the recipients must be indicated in a single command.
To delete a setting for the recipients, use “VUOTO” .
For
example:
INVIO ALLARME ALIMENTAZIONE VUOTO deletes all the recipients in the case of
an electrical network failure alarm
Definition of the alarm from digital input
It is possible to specify the condition for which an alarm occurs in the digital input.
In particular, the following must be defined:
– the status (open or closed)
– the delay, or after how much permanence time of a certain status an alarm can
be considered
The alarm syntaxes are:
IMPOSTA ALLARME CONTATTO APERTO
[delay]
IMPOSTA ALLARME CONTATTO CHIUSO
[delay]
where:
[delay] numeric value that indicates after how many seconds of permanence in
the open or closed state an alarm must be considered