- 32 -
Mithos GSM Programmable Thermostat User Manual
The number in the telephone book that made the call will receive a text message
informing of the programmable thermostat status. Some examples:
MITHOS=ACCESO
(AUTOMATICO)
MITHOS=SPENTO (ANTIGELO=02.0 C)
MITHOS=ACCESO (MANUALE=20.0 C)
MITHOS=SPENTO
(ANTIGELO=DISABILITATO)
Setting the operating mode
It is possible to set the operating mode for the instrument and even set the timer if
you want to maintain a certain operation only for a certain period of time.
The syntaxes of the commands to send are:
MITHOS ACCESO AUTOMATICO
[period] [unit of measurement]
MITHOS SPENTO
[period] [unit of measurement]
MITHOS ACCESO MANUALE
[period] [unit of measurement]
where:
MITHOS ACCESO AUTOMATICO for setting automatic operation
MITHOS SPENTO for setting off operation (with possible antifreeze)
MITHOS ACCESO MANUALE for setting manual operation
[period]
indicates any timer period (values between 0 and 99)
[unit of measurement]
indicates the unit of measurement for the timer period
(G = days, H = hours)
Note: the parameters [period] and [unit of measurement] are optional.
Note: the rules for the timers are the same as those defined on pages 16-17.
Some
examples:
MITHOS ACCESO AUTOMATICO sets automatic operation (no timer)
MITHOS
MANUALE sets manual operation (no timer)
MITHOS AUTOMATICO 20 H sets automatic operation for 20 hours, at the end of
which the programmable thermostat will switch to
off/antifreeze operation
MITHOS SPENTO 2 G sets off operation for 2 days, at the end of which the
programmable thermostat will return to the operation it had
before being shut off (automatic or manual)
The number in the telephone book that sent the command will receive a text
message informing of the programmable thermostat status.