- ENGLISH - 

TRD03B0000SE 036247 270121 

 

Full batteries life.

 

 

Low batteries life; need replacement.

 

 

Temperature set in Comfort mode.

 

 

Temperature set in Economy mode.

 

 

Thermostat switched off, OFF mode.

 

 

Active  antifrost  mode,  the  thermostat  sets  to  antifrost 
temperature.

 

 

Heating mode output.

 

 

Cooling mode output.

 

 

The thermostat has sent a radio command. 

 

The thermostat is under configuration.

 

 

The thermostat is in 'Test' mode, and it transmits a 
command every 2 seconds for the pairing procedure 
of a receiver. 

 

T set-point displayed.

 

EEE 

If 

P09

  is  set  on  EXT,  the  utilized  external  sensor  is 

faulty or unplugged. 

OVERVIEW 

This  device  is  a  radio-controlled  display  thermostat  to  control 
the room temperature with the option to choose among different 
setting  modes  and  related  set-point  temperatures:  Comfort, 
Economy, Off/Antifrost. 
The  thermostat  is  set  by  default  to  operate  in  Comfort, 
Economy  and  Antifrost  modes;  it  can  be  adapted  to  the 
different installation requirements by modifying the settings and 
the final user intervention can be restricted, aiming to  optimize 
environment comfort and energy saving. The thermostat can be 
used in both heating and cooling systems and it is also suitable 
for floor heating systems. 

 

START-UP 

When activating for the first time, open the thermostat cover, as 
shown in paragraph 'INSTALLATION' in (

C

 of Fig. 6), and insert 

batteries  with  the  correct  polarity.  Batteries  shall  be  1.5V 
alkaline AA type. 

 

Heating/Cooling Set-up 

The thermostat is set by default  in heating mode. 
Hold down '        ' for 10 seconds to modify the regulation mode. 

A.

 Cooling mode will be set if the thermostat was previously set 

on  heating  and  the  symbol  '        '  will  flash  on  display  for  8 
seconds. 

B. 

Heating mode will be set if the thermostat was previously set 
on  cooling  and  the  symbol  '      '  will  flash  on  display  for  8 
seconds. 

The lit icon '   ' Flame indicates that heating mode is on during 
normal operation; on the contrary, cooling activation is signalled 
by the Snow icon '      '. 

 

Regulation mode set-up

 

There are 3 ways to set the room temperature that can either 
be selected by pressing '          '. 

 

Comfort:

 

The thermostat sets the room temperature in 
comfort  mode;  this  is  normally  the  preferred 
temperature during the day-time. 

Economy:

 

The  thermostat  sets  the  room  temperature 
according  to  the  economy  mode  (this  is 
usually  the  preferred  temperature  during 
night time). 

OFF / Antifrost:

  Turn off the thermostat; the display will show 

the  text  'OFF'.  If  the  thermostat  was  set  to 
heating  mode  and  the  antifreeze  function  is 
active,  the  icon  '        '  will  appear  on  the 
display;  in  this  case  the  room  temperature 
will  be  regulated  according  to  the  value  set 
for  the  antifreeze  temperature,  in  parameter 

P02

.  

 

(see paragraph 'INSTALLER CONFIGURATION'). 

 

The  thermostat  is  set  by  factory  default  to  use  OFF,  Comfort 
and Economy modes. 

 

Through the installer parameter 

P01

 it is possible to deactivate 

the option to select one or more functions (see the 'INSTALLER 
CONFIGURATION' paragraph). 
Pressing  '              '  cyclically  scroll  among  the  different  activated 
setting modes: 
 
 
 

 

Once a setting mode is set, it remains so until the '       ' key is 
pressed again. 
See the 'INSTALLER CONFIGURATION' paragraph for further 
information on how to configure the setting modes. 

 

Set-point Temperature 

 
 
 
 
 
 

 

 

  

Fig. 2 

 

During  normal  operation  the  display  shows  the  room 
temperature  detected  and  the  icon  for  the  selected  operating 
mode.  In  order  to  show  the  relevant  set-point  temperature 
press  any  of  the  keys  '

'  or  '

':  the  display  will  show  the  set-

point  temperature  and  the  icon  '      '  will  turn  on  (thus  showing 
that the value shown refers to the set-point temperature). 
The icon '    ' turns on along with icon ' 

     

' thus meaning that the 

display is showing the ‘Comfort’ set-point temperature or as an 
alternative, together with icon '    ' thus meaning that the display 
is showing the ’Economy’ set-point temperature. 
Pressing the key '

' or '

' results in modifying the current set-

point  temperature.  By  pressing  the  key  '

'  or  '

'  the  set-point 

temperature  digits  start  flashing  to  point  out  that  the  set-point 
can be changed. 
Pressing  the  key  '            '  while  the  display  is  showing  the 
‘Comfort’  set-point  temperature  results  in  switching  to  the 
‘Economy’ set-point display. 
On the other hand when the display shows the 'Economy' set-
point pressing the '        ' key results in showing the 'Comfort' 
set-point. 
A further pressing of the '

        

' key results in showing the room 

temperature, as well as after a few seconds of inactivity on the 
keys. 

 

EXTERNAL NTC SENSOR 

The  thermostat  features  an  input  ('REMOTE  SENSOR', 

B

  in 

Fig.  6)  to  connect  an  external  NTC  sensor  (optional) 
alternatively the internal one. 
The  external  sensor  can  be  used  to  measure  the  room 
temperature when the thermostat is installed in a position which 
does not allow a correct room temperature measurement. 
When  the  installation  requires  an  installation  with  a  remote 
sensor, it is necessary to set correctly the parameter 

P09

 and 

connect a 10 kOhm @ 25°C NTC sensor. If there is any doubt 
about  the  type  of  sensor  to  be  connected,  please  consult  the 
manufacturer. 
The  thermostat  leaves  the  factory  already  set  to  operate  with 
the internal sensor. 

 

RADIO SYSTEM CONFIGURATION 

Check 

on 

the 

paragraph 

'COMPATIBILITY 

WITH 

BIDIRECTIONAL WIRELESS SYSTEM', that the receiver to be 
paired with the thermostat is a compatible one. 
Check if the receiver correctly receives the wireless thermostat 
signals  before  installing  the  latter  in  the  desired  position.  The 
operation  is  performed  by  activating  the  'Test'  function  by 
simultaneously pressing '

' and '

' buttons. 

The  thermostat  displays  the  icon  '

TEST

'  and  continuously 

transmits  switch-on  and  off  controls  to  the  receiver,  with  a  2 
second  pause  between  them,  in  'Test'  mode;  every  time  the 
thermostat transmits a radio command and only if it receives an 
acknowledgment from the receiver, the symbol '       ' lights up 
on the display. The 'Test' mode can be interrupted at any time 
by  pressing  '                  '.  However,  the  'Test'  mode  automatically 
ends after approx.17 minutes. 
'Test'  mode  must  also  be  activated  to  pair  a  receiver  to  the 
thermostat, this procedure allows the devices to exchange and 
memorize their address which will allow them to recognize each 
other. In 'Test' mode, in addition to the text '

TEST

', the display 

will also show '

nd1

' or '

Ed1

': 

nd1

: new device 1 - if no receiver has ever been paired. 

Ed1

: existing device 1 - if a receiver has already been paired. 

To  pair  a  receiver  with  the  thermostat,  activate  the  pairing 
procedure on the receiver by pressing the relevant button, after 
about 10 seconds, if the operation is successful, the thermostat 
will confirm the pairing with the text 

dL1

: device learned 1 after 

a  few  moments  the  thermostat  in  'Test'  mode  will  return  to 
display 

Ed1

: existing device 1 the receiver will also confirm the 

successful  pairing,  with  an  alternating  red-green-red-green 
flashing of the LED. 
Once  paired,  the  receiver  will  begin  to  receive  the  Test 
commands  sent  by  the  thermostat  and  the  relay  of  its  output 
must  continuously  switch  on  and  off  every  2  seconds,  the 
status is also indicated by the relevant LED. If the receiver has 
no  output  relay,  the  LED  will  flash  green  at  each  reception  of 
the Test command. Observe the LED on the receiver to confirm 
that  the  thermostat  is  communicating  correctly  with  the 
receiver. Correct communication with the  receiver can also  be 
checked  on  the  thermostat:  the  '          '  symbol  lights  up  on  the 
thermostat display for a few moments each time the thermostat 
receives an acknowledgment command from the receiver. It is 
possible to pair more receivers to the same thermostat up to a 
maximum of 6. During the Test mode, by pressing the '

' or '

it is possible to select 

nd2

 (new device 2) to 

nd6

 (new device 

6) and perform a pairing procedure for each additional receiver. 
During the 'Test' mode the thermostat will send commands and 
will receive acknowledgment only from the selected receiver in 
order  to  check  the  correct  communication  with  each  single 
paired receiver. 
Make  sure  that  the  two  devices  still  correctly  communicate 
when positioning the thermostat in the destination area. 
The  output  relay  always  remains  on  or  off  if  the  thermostat  is 
positioned  too  far  from  the  receiver:  if  so,  we  recommend  to 
find  a  better  position,  possibly  closer  to  the  receiver,  and 
ensure it is not near metal screens or reinforced concrete walls 
that might weaken radio transmission. 
The  signal  quality  can  be  checked  with  the  receiver  (see  the 
relative documentation for further information). 
 

CANCELLATION OF A RECEIVER 

In case you have paired the wrong receiver, or need to replace 
a  receiver,  it  is  necessary  to  cancel  the  pairing  between  the 
thermostat and the receiver. 
The  cancellation  procedure  takes  place  by  starting  the  'Test' 
mode  as  explained  in  the  previous  paragraph,  select  the 
receiver  to  be  deleted 

Ed1

-

Ed6

  with  the  '

'  or  '

'  keys,  press 

and hold the '         ' key for 10 seconds, after cancellation the 
display will show 

nd1

 (

nd1

-

nd6

). 

To  avoid  malfunctions  of  the  radio  system  it  is  important  that 
the  receiver  to  be  cancelled  is  powered  and  turned  on  as  the 
receiver  must  receive  the  pairing  cancellation  command  from 
the thermostat. 

 

INSTALLER CONFIGURATION 

The  installer  configuration  allows  to  define  the  thermostat 
operation to set it to the different kinds of rooms and systems. 
Hold '

' and '       ' simultaneously pressed for a few seconds 

until the '    ' symbol and the word ' 

Con

 ' (configuration) appear 

on the display, to access the configuration parameter. From this 
moment, pressing '        ', will scroll among the different installer 
parameters  identified  with  '

P

'  and  by  the  parameter  number, 

from 

P01 

to 

P17.

 

The end of configuration is indicated with the word '

End

'. Press 

'      ' again to save the configuration and then the thermostat 
switches to normal operation. 
At any time, by pressing for a few seconds the '      ' key, the 
configuration  menu  is  quit  without  saving  any  changes  made. 
While  scrolling  through  the  parameters,  pressing  the  '

'  or  '

key  once, the display shows the current parameter setting. To 
modify  the  selected  parameter  press  again  the  '

'  or  '

'  keys; 

C

SET

TEST

OFF / 

CONTROLS LAYOUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KEY: 

 

A  Key ' 

 ':

 multifunction key

 

 

Normal operation 

 

- If pressed once shows the set-point temperature. 

 

- If pressed repeatedly increases the set-point temperature. 

 

In setting mode 

 

- If pressed once shows the set parameter. 

 

- If  pressed  repeatedly  changes  the  selected  parameter 
(increases the value). 

 

B  Key '      ':

 multifunction key: 

 

Normal operation 

 

- Sets  the  regulation  mode  (according  to  parameter 

P01

): 

Comfort => Economy => OFF/ANTIFROST. 

 

- If  pressed  for  more  than  10  seconds,  it  reverses  the 
operation logic: Heating 

 Cooling. 

 

In setting mode 

 

- Shows the parameters list

 

 

C  Key ' 

 ': 

Multifunction key

 

 

Normal operation: 

 

- If pressed once shows the set-point temperature. 

 

- If  pressed  repeatedly  decreases  the  set-point 
temperature. 

 

In configuration mode 

 

- If pressed once shows the set parameter. 

 

- If  pressed  repeatedly  changes  the  selected  parameter 
(decreases the value). 

 

DISPLAY INDICATIONS 

The meaning of the symbols appearing on the display is given 
below: 

SET

TEST

C

Fig. 1 

SET

TEST

F

C

TR D03B

 

WIRELESS DIGITAL THERMOSTAT  

 

Bidirectional wireless technology 

 

Blue backlight display 

 

Heating/Cooling switching can be controlled on the 
thermostat or on the receiver 

 

User limitations to set the Set-point temperatures 

 

Internal sensor and input plug for remote sensor 

 

Low battery icon 

Via del Commercio, 9/11 36065 Mussolente VI - ITALY 
Tel.: +39.0424.567842 - Fax.: +39.0424.567849 
http://www.seitron.it - e-mail: [email protected] 

Reviews: