holding down the '

' or '

' keys, allows to increase or decrease 

the value quickly. 
 

Reset installer configuration 

To  reset  installer  configuration,  in  order  to  bring  all  the 
parameters  to  factory  default  values,  access  the  configuration 
and,  when  the  display  shows  '

Con

',  simultaneously  press  '

and '

' for a few seconds until the screen goes back to normal 

mode. 
 

Description of configuration parameters 

The installer configuration parameters are shown in table 1 and 
explained below. 

 

Some  installer  parameters  may  not  be  displayed  as  only 
the parameters currently required by the configuration are 
shown  (the  configuration  value  of  a  parameter,  may 
exclude one or more subsequent parameters). 

 

P01

:  allows  to  customise  the  regulation  modes  that  can  be 

selected with the key '        '. The regulation modes available 
are Comfort, Economy and OFF: each of these can be enabled 
or disabled by changing 

P01

The OFF mode will be replaced by Antifrost mode in case 

P02 

is set with an antifrost temperature. 
 

P02

:  by  this  parameter  the  Antifrost  temperature  can  be  set: 

this will be maintained when the thermostat is turned off. 
The antifrost temperature can be set in the range 0.5 .. 25 °C or 
disabled by setting the parameter until the value ‘no’ appears. 
By factory default this parameter is set at 6 °C. 

 

P03

: room temperature offset. 

The detected room temperature can be corrected by ±10.0 °C 
with the offset, in order to correct any systematic reading error 
due to thermostat positioning in unsuitable  areas to detect the 
room temperature. 
By default the device is set with 0.0 °C offset. 

 

P04

: sampling time. 

To  ensure  long  battery  life,  the  thermostat  waits  a  period  of 
time between one transmission and another. The period can be 
chosen  from  1  to  10  minutes.  Therefore  it’s  normal  that  the 
temperature  displayed  is  not  immediately  updated;  moreover 
for the same reason it can be necessary to wait some minutes 
(up  to  the  sampling  time  value)  to  see  the  receiver's  output 
switching. A sampling time of 1 to 3 minutes should be chosen 
when  the  heating/cooling  system  is  fast,  while  with  slower 
heating  systems  based  on  radiators  or  floor  heating,  even  a 
time  of  10  minutes  allows  excellent  accuracy  and  comfort.  In 
any case, at any time, pressing the '       ' key forces an update 
to  the  receiver.  Choosing  a  longer  sampling  time  will  get  a 
longer battery life. 

 

P05

 and 

P06

: these two parameters set the temperature range 

within which the set-point temperature can be chosen when the 
thermostat is in heating mode. 

P05 

is the lower limit and can be 

freely set from 5.0 .. 35.0 °C, while 

P06

 is the higher limit that 

can be set in a range from the lower limit, chosen in 

P05

, up to 

35.0°C. 
Therefore, the widest temperature range is 5 .. 35 °C and can 
be easily reduced based on installation requirements. 

 

P07

 and 

P08

: these two parameters configure the temperature 

range within which the set-point temperature  can be set when 
the  thermostat  is  in  cooling  mode,  with  the  same  logic  of  the 
previous two points. 
The set-point temperature  limits are  re-defined upon changing  
the cooling/heating settings. 

 

P09

: NTC sensor configuration. 

The  thermostat  is  set  by  default  prepared  to  operate  with  the 
internal  NTC  (

P09=  Int

).  Alternatively  to  the  internal  sensor  a 

remote  sensor  can  be  wired    to  the  connector  'REMOTE 
SENSOR',  shown  with   

B

  in  Fig.  6  and  set  parameter  P10  as 

'Ext': this way the internal sensor is disabled while the external 
is  enabled.  Make  sure  to  use  the  proper  remote  sensor  type, 
and respect the maximum wire length allowed. 

 

P10

: reserved parameter, do not modify. 

 

P11

: reserved parameter, do not modify. 

 

P12

:  hysteresis,  represents  the  amplitude  of  the  hysteresis 

which will be used for the room temperature regulation. 

 

P13

: reserved parameter, do not modify. 

 

P14

: reserved parameter, do not modify. 

 

P15

: reserved parameter, do not modify. 

 

P16

: reserved parameter, do not modify. 

 

P17

: set-point temperature displayed by default.  

The thermostat is set by factory default on  “no” parameter, so 

the thermostat shows the detected room temperature, but if this 

parameter s set on “YES”, the displayed temperature is the set 

point  one,  but  the  room  temperature  can  be  temporarily 

displayed after the set-point temperature is modified. Instead, if 

the parameter  is set on “

OnL

”, “set-point only”, the thermostat 

shows  only  the  set-point  temperatures  (set-point  comfort,  set-

point  economy)  and  it  is  not  possible  to  display  the  room 

temperature.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
WARRANTY 

In  the  view  of  a  constant  development  of  their  products,  the 
manufacturer  reserves  the  right  to  amend  technical  data  and 
features  without  prior  notice.  The  consumer  is  guaranteed 
against  any  lack  of  conformity  according  to  the  European 
Directive  1999/44/EC  as  well  as  to  the  manufacturer’s 
document  about  the  warranty  policy.  The  full  text  of  the 
warranty is available on request from the seller. 

TEMPERATURE REGULATION 

The  thermostat  regulates  the  output  on  the  receiver  with  ON/
OFF type regulation with configurable hysteresis on parameter 

P12

 

DISPLAY BACK-LIGHTING  

Switch-on  of  the  display  Switch-off  is  automatic  after  20 
seconds from last button pressure. 

 

BATTERIES INSERTION/REPLACEMENT 

The  display  permanently  shows  the  batteries  charge  state  by 
means of symbol '           '. Batteries are charged to maximum if 
all three level indicators inside the symbol are on. 
On the contrary, the batteries are drained and must be replaced 
when the symbol appears completely empty '          '. 
The symbol '         ' flashes when the batteries are excessively 
drained to allow radio transmission.  
For batteries replacement proceed as explained on points 

1

2

 

and 

4

 at page 3.   

  

COMPATIBILITY  WITH  BIDIRECTIONAL  WIRELESS 
SYSTEM 

The  thermostat  works  with  the  following  bidirectional  wireless 
technology receivers: 

 

DA0311

: Modbus receiver. 

 
TECHNICAL FEATURES 

Power supply: 

2  x  1.5V     

 

alkaline  AA  type 

batteries 

Duration of the batteries: 

5 years with P04=10 minutes 

 

3 years with P04=3 minutes 

Frequency: 

868.450 MHz 

Modulation: 

GFSK 

Max. RF power transmitted:  1 mW 
Type of antenna: 

Internal 

Max. distance from receiver:  >300 m in free field 
 

>50  m  in  buildings  (depending  on 
the building and environment) 

  
Temperature sensor (internal sensor or remote as alternative) 
Regulation range: 

5.0 .. 35.0°C 

Hysteresis: 

0.2°C configurable 0.1 .. 5.0 °C 

Type of sensor: 

NTC 10kohm ±1% @25°C  

 

B(25/85)=3977 

Resolution: 

0.1°C 

Range: 

-9.9°C .. +50.0°C 

Precision: 

±1.0°C 

  
Maximum length of the wires 
to the remote sensor: 

15 m 

Antifrost: 

6.0°C adjustable OFF

|

0.5 .. 25.0 °C 

Offset: 

± 10.0°C. (Default 0.0°C) 

Backlighting switch-off: 

20 seconds from last pressing 

Protection rating: 

IP 30 

Type of action: 

Overvoltage category: 

II 

Pollution degree: 

Tracking Index (PTI): 

175 

Class of protection against 
electric shocks: 

III 

Rated impulse voltage: 

2500V 

Number of manual cycles:  50000 
Number of automatic cycles: unlimited 
Software class: 

EMC test voltage: 

3V 

EMC test current: 

35mA 

Distances tolerances fault 
mode ‘short’ exclusion: 

±0,15mm 

Ball pressure test temp.: 

75° C 

Operating temperature: 

0°C .. +40°C 

Storage temperature: 

-10°C .. +50°C 

Humidity limits: 

20% .. 80% RH (non-condensing) 

Enclosure: 

Material: 

ABS+PC V0 self-extinguishing 

 

Colour: 

Signal White (RAL 9003) 

Weight: 

~ 115 gr

 

 

CLASSIFICATION UNDER REG. 2013.811.EC 

Class: 

 

 

 

Contribution to energy efficiency: 

1% 

 

DIMENSIONS 

 
 

 

 

 
 
 
 

 
 

 

 

 

 

 
 
 
 

 
 
 

 
 

 

 

23.6mm

85mm

85m

m

Reviews: