background image

MODEL

2000NC

USER MANUAL

Builder Series

5-2 Day Programmable

Single Stage Heat/Cool

Digital Thermostat

Compatible with low voltage single stage gas, oil 

or electric heating or cooling systems, including 

single stage heat pumps.  This thermostat can 

also be used on 250mv to 750mv millivolt heating 

only systems.  Do not use this thermostat on 

applications with voltages above 30 Volts AC.

READ ALL INSTRUCTIONS BEFORE PROCEEDING

CONTENTS

WARNING!

Important Safety Information

SPECIFICATIONS
INSTALLATION
TESTING YOUR NEW THERMOSTAT
PROGRAMMING

1

2
3
4

5
6
7

• Always turn off power to the air conditioning or heating system prior to installing,    

  removing, cleaning or servicing thermostat.

• Read this manual thoroughly prior to installing, programming or operating 

  this thermostat.

• This thermostat is designed for use with a 24 Volt-AC low voltage single stage  

 

  gas, oil or electric heating or cooling systems.

• Do not use this thermostat on applications with voltages above 30 Volts AC.

• This thermostat requires two (2) properly installed "AA" alkaline batteries to  

 

  provide power for the thermostat to properly control the system operation.

• Wiring must conform to all building codes and ordinances as required by local and   

  national code authorities having jurisdiction.

• Do not short (or jumper) across terminals on the gas valve or at the heating or  

 

  cooling system control board to test the thermostat installation.  This could  

 

  damage the thermostat and void the warranty.

• Do not select COOL mode of operation if the outside temperature is below 50˚ F    

  (10˚ C).  This could possibly damage the controlled cooling system and may cause   

  personal injury.

• This thermostat should only be used as described in this manual.  Any other use is

   

 

not recommended and will void the warranty.

SPECIFICATIONS

1

1

4.

   After labeling and removing all wires from terminals, unscrew the existing  

 

 

thermostat sub-base from wall. Be sure to secure wires to prevent them from  

 

 

slipping back into the hole in the wall.

NOTE:

  

This thermostat is designed for use with a 24 Volt AC low voltage single 

stage gas, oil or electric heating or cooling systems, including single stage heat 

pumps. This thermostat can also be used on 250mv to 750mv millivolt heating only 

systems. Do not use this thermostat on applications with voltages above 30 Volts AC.

2.2

Installing Your New Thermostat

NOTE:

 

 If you are installing this thermostat in a new installation be sure to locate 

the thermostat 4 to 5 feet above the floor in accordance with applicable building 

codes. Be sure to install the thermostat in a location that provides good airflow 

characteristics and avoid areas behind doors, near corners, air vents, direct sunlight 

or near any heat generating device. Installation in any of these areas could impact 

thermostat performance.

1.

   Always turn off power to the air conditioning or heating system prior to installing  

 

 

your new thermostat.

2.

   Place system switch on front of thermostat to the 

OFF

 position.

3.

   Place fan control switch on front of thermostat to the 

AUTO

 position.

4.

   Remove front of thermostat body from sub-base by pressing release latch on bottom   

 

of front body.

5.

   Place the thermostat sub-base against wall in the desired thermostat location. 

•   Electrical Rating:  24 Volt AC (18-30 Volt AC)

       1 amp maximum load per terminal

       2 amp total maximum load (all terminals)

•  Control Range:  45˚ - 90˚ F (7˚ - 32˚ C)

•   Accuracy:   +/- 1˚ F (+/- .5˚ C)

•   DC Power: 3.0 Volt DC (2 AA Alkaline batteries included) 

•   Compatibility:  Compatible with low voltage single stage gas, oil or electric  

     

    heating or cooling systems, including single stage heat pumps.  This thermostat        

    can also be used on 250mv to 750mv millivolt heating only systems.

•   Terminations:  Rc, Rh, O/B, Y, W, G

INSTALLATION

2

2.1

Replacing Existing Thermostat

1.

  Always turn off power to the air conditioning or heating system prior to 

  removing existing thermostat.

2.

  Remove the cover of your old thermostat and locate the wire terminals.  

  Do not remove wires from terminals yet.

3.

  Using small pieces of masking tape, label wires prior to removal from terminals.     

  Use the chart below to determine the new terminal designations for your 

  new thermostat.

Old Terminal from 

New Terminal for

Existing Thermostat  New Thermostat  Terminal Description

V or Rc 

Rc 

Cooling Transformer

M, 4, Rh, or R 

Rh 

Heating Transformer

B or O 

O/B 

Reversing Valve (Cooling or Heating)

Cooling Control

H, W or 4 

Heating Control

G or F 

Fan Control

None-Cap the wire  24 Volt AC, Transformer Common

ADDITIONAL OPERATION FEATURES
TROUBLESHOOTING
WIRING DIAGRAMS

®

Summary of Contents for 2000NC

Page 1: ...ermostat can also be used on 250mv to 750mv millivolt heating only systems Do not use this thermostat on applications with voltages above 30 Volts AC 2 2 Installing Your New Thermostat NOTE If you are...

Page 2: ...Press the button on the keypad until the setpoint temperature is a minimum of 3 degrees lower than the current room temperature 6 The cooling system should start within several seconds Place the syste...

Page 3: ...ended hold time 1 In normal operating mode press and hold the RETURN button for 4 seconds The LCD display will show d1 x where x equals the F C differential setting This is the current temperature dif...

Page 4: ...ay Program Group will be displayed The display will show M TU W TH F to indicate the Weekday group is being programmed The hour portion of the setpoint time and the AM PM indicator will be flashing AD...

Page 5: ...oling instead of heating Check thermostat wiring to make sure that the heating and cooling stages are connected to the correct terminals on the wiring terminal block For heat pump systems check that t...

Page 6: ...or too cold See Review Set Temperature section 5 1 of this manual to verify the current set point and make any modifications that are necessary LO is shown in the thermostat display where the room te...

Page 7: ...option any Braeburn thermostat under warranty provided it is returned postage prepaid to our warranty facility in a padded carton within the warranty period with proof of the original date of purchase...

Reviews: