background image

Zigbee Heating Thermostat

 

ROB

_

200-040-0

Function introduction

Important: 

Read All Instructions Prior to Installation

Front side

1. Product Data

F

TIME/SHIFT button, to set 

time schedule of the 

device quickly and move 

the cursor

Function button, to 

confirm, save setting

Mode button, to switch 

operation modes and quit

Move up and move down 

buttons

LED Display

59 mm

80 mm

59 m

m

80 m

m

10 mm 10 mm

31 mm

Back side

NTC

L    L   N   N

AC Power input

Floor temp sensor

Output

Home Interface

SR-ZG9092A

Radio Frequency
Input Voltage
Output Voltage
Max Load
Max Current
Power Consumption
Ambient Temperature
Set Temperature Range
Hysteresis

Floor sensor type

Control Type

Approvals

1. NTC/10K B(25/50

)=3950 (default)

2. NTC/15K B(25/50

)=3950

3. NTC/50K B(25/50

)=3950

4. NTC/100K B(25/50

)=3950

5. NTC/12K B(25/50

)=3950

Control type means which temperature sensor the device refers to 

when it adjust temperature.

Room sensor

: adjust temperature refers to room temperature 

(factory default type).

Floor sensor

: adjust temperature refers to floor temperature.

Room+Floor sensor

: adjust temperature refers to both room 

temperature and floor temperature.

CE

,

LVD

: EN 60730-1:2016;A1, EN IEC 60730-2-9:2019;A1

EMC & RF

: EN IEC 61000-3-2:2019, EN 61000-3-3:2013+A1:2019,

EN 60730-1:2016+A1:2019, EN 60730-2-
19:2019+A1:2019+A2:2020, EN 50663:2017;ETSI EN 301 489-
1V2.2.3, ETSI EN301 489-3V2.1.1
ETSI EN300 220-1 v3.1.1., ETSI EN300 220-2 V3.2.1

RED certificate

: 2014/53/EU

• 

The Zigbee HVAC controller is a wireless thermostat for heating system, which complies to Zigbee 3.0 

wireless protocol standards. The thermostat has 4 operation modes which can be controlled manually and 

locally or through remote controlled through Zigbee gateway controller.

• 

All setup is performed via supported IEEE 802.15.4-based control platforms and other Zigbee3.0 compatible 

control systems. Appropriate gateway control software allows for adjustment of control mode, control type, 

schedule etc.

• 

Sensors: Air temperature

• 

THERMOSTAT MODE: OFF, HEAT, ENERGY HEAT, AWAY, DRY

• 

Measurement range: –10°C to +60°C

• 

Accuracy: ±0.1°C 

• 

WARNING: Electrical power must be switched off during installation

2.4GHz
EU: AC200-240V, 50/60Hz
EU: AC200-240V
3680W @ 230V (resistive load)
16A
<2W
0°C to 40°C (during operation)
0°C to 40°C
0.5°C to 2°C (default 0.5°C)

Control Mode

OFF, HEAT, ENERGY HEAT

AWAY, DRY

Wiring Requirement

Current 

≤ 

13A - 1.5mm² wire

Current > 13A to 16A - 2.5mm² wire

 

IP Rating
Control Pollution Degree (Method D)
Rated Impulse Voltage (Method D)
Relative Humidity
Dimensions

IP21

8% to 80%

4kV

80x80x52mm

pollution degree 2

Revised 11.08.2021

Summary of Contents for ROB-200-040-0

Page 1: ...EMC RF EN IEC 61000 3 2 2019 EN 61000 3 3 2013 A1 2019 EN 60730 1 2016 A1 2019 EN 60730 2 19 2019 A1 2019 A2 2020 EN 50663 2017 ETSI EN 301 489 1V2 2 3 ETSI EN301 489 3V2 1 1 ETSI EN300 220 1 v3 1 1...

Page 2: ...1 Switch Operation modes Short press button on Home interface to switch operation modes the icons of Away Manual Comfort Automatic Energy Save Drying OFF modes will be displayed alternatively for 3 s...

Page 3: ...x2001 of Thermostat Cluster 0x0201 when this value is set as 0 this function is disabled Over heat alarm interface is as follow Note to cancel over current alarm or over heat alarm just press and hold...

Page 4: ...ribute TemperatureDisplay 0x1008 of Thermostat Cluster 0x0201 Operate Brightness Mid Level by default The OLED display brightness when operate the device Adding to a Zigbee Network Operate your Zigbee...

Page 5: ...server Scenes Allows storing one or more scenes per group where each scene consists of a pre set on off state value You may either store the current values as a scene or provide scene settings when ad...

Page 6: ...format allows 0 1 C Default value 0 0x0011 int16S reportable OccupiedCoolingSetpoint This system is not invalid 0x0012 int16S reportable OccupiedHeatingSetpoint Range is 0 4000 the maximum resolution...

Page 7: ...16U read only reportable RMSVoltage Single phase valid voltage unit is V 0x0508 int16U reportable read only RMSCurrent Single phase valid current unit is A 0x050B int16S reportable read only ActivePow...

Page 8: ...executed when away mode is selected Check whether away mode time is set as 0 or within valid time range 4 Over heat alarm when power on the device Possible reason the set sensor type is not correct o...

Reviews: