0x1007
ENUM8
reportable
ModeAfterDry
The mode after Dry Mode:
Value=0 : OFF
Value=1 : Manual mode
Value=2 : Auto mode –schedule (default)
Value=3 : Away mode
0x1224
0x1008
ENUM8
reportable
TemperatureDisplay :
Value=0 : Room Temp (Default)
Value=1 : Floor Temp
0x1224
0x1009
INT8U
reportable
WindowOpenCheck
The threshold to detect open window, range is 0.3-8, unit is
0.5ºC,
0 means disabled, default is 0
0x1224
0x100A
INT8U
reportable
Hysterersis
Hysterersis setting, range is 5-20, unit is 0.1ºC, default value
is 5
0x1224
0x2001
INT8U,
reportable
AlarmAirTempOverValue
Room temp alarm threshold, range is 0.20-60, unit is 1ºC,
0 means disabled, default is 45
0x1224
Command supported:
Command
Description
0x0000
Setpoint Raise/Lower
Increase or decrease the set temperature according to current mode, unit is
0.1ºC
5.2.5 Simple Meter-0x0702 (Server)
Attributes supported:
Attribute
Type
Description
0x0000
unsigned48 ,
read-only,
reportable
CurrentSummationDelivered
Indicates the current amount of electrical energy delivered to the load.
0x0200
bitmap8 ,
read-only
Status
Flags indicating current device status, always is 0x00
0x0300
enum8 ,
read-only
UnitOfMeasure
The unit of metering data, this is always kWh(0x00)
0x0303
map8 ,
read-only
SummationFormatting
The decimal point on the left and right sides of the data, this is always 0x00
0x0306
bitmap8,
read-only
MeteringDeviceType
Metering data type, this is always Electric Metering (0x00)
5.2.6 Electrical Measurement-0x0b04(Server)
Attributes supported:
Attribute
Type
Description
0x0000
bitmap32 ,
read-only
MeasurementType
Indicates the physical entities that this devices is able to measure. Supports
only bit0: Active measurement (AC)
0x0505
int16U ,
read-only,
reportable
RMSVoltage
Single phase valid voltage, unit is V
0x0508
int16U ,
reportable,
read-only
RMSCurrent
Single phase valid current, unit is A
0x050B
int16S ,
reportable
read-only
ActivePower
Single phase valid power, unit is W
0x0600
int16U,
read-only
ACVoltageMultiplier
0x0601
int16U,
read-only
ACVoltageDivisor
Used together with above attributes, the real displayed voltage =
RMSVoltage* ACVoltageMultiplier
/ ACVoltageDivisor
0x0602
int16U,
read-only
ACCurrentMultiplier
0x0603
int16U,
read-only
ACCurrentDivisor
Used together with above attributes, the real displayed current = RMSCurrent
* ACCurrentMultiplier
/ ACCurrentDivisor
0x0800
int16U,
ACAlarmsMask
Specifies which configurable alarms may be generated, only
Bit1: Current Overload is set, if set=0, then ACCurrentOverload=0, over
current will not be detected
0x0802
int16S ,
reportable
read-only
ACCurrentOverload
Alarms when the current is over a certain value, 0, 10-16, unit is A
Proprietary Attributes:
Attribute
0x0000
Type
Int8u,
reportable
Manufacturer code
0x1224
Description
OverCurrent
Over current value set by the user, range is 0, 10-16,
ACCurrentOverload will change spontaneously if this
value is modified.
5.2.7 Alarm-0x0009(Server)
Please set a valid value for ACAlarmsMask of Electrical Measurement.
The Alarm Server cluster can generate the following commands
CmdID
Description
0x00
Alarm:
The alarm code of Electrical Measurement is 0,
Proprietary command,
Manufacturer code=0x1224
CmdID
Description
0x00
Room air temperature over heat, not alarm code
0x2002
ENUM8
reportable
Away Mode Set:
Value=0: not away (default)
Value=1: away
0x1224
0x1006
INT8U
reportable
DryTime
The duration of Dry Mode, range is 5-100, unit is min.
Default value is 5.
0x1224
0x1005
INT8S,
reportable
FloorSenserCalibration
The temp compensation for the external (floor) sensor, range
is -30-30, unit is 0.1°C. default value 0
0x1224